| 数据搜索系统,热门电子元器件搜索 |
|
FP1108L2-R150-R 数据表(PDF) 2 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
FP1108L2-R150-R 数据表(HTML) 2 Page - Eaton All Rights Reserved. |
|
2 / 6 page ![]() 2 Technical Data 10448 Effective October 2015 FP1108L1 and FP1108L2 High frequency, high current power inductors www.eaton.com/elx Product Specifications Part Number8 OCL1 (nH) ±10% FLL2 (nH) minimum I rms 3 (amps) I sat1 4 (amps) I sat2 5 (amps) I sat3 6 (amps) DCR (mΩ) ±10% @ 20°C K-factor7 L1 Version FP1108L1-R105-R 105 76 64 81 77 72 0.10 422 FP1108L1-R150-R 150 108 64 57 49 45 0.10 422 FP1108L1-R180-R 180 129 64 47 41 37 0.10 422 L2 Version FP1108L2-R150-R 150 108 48 55 50 46 0.18 390 1. Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.1Vrms, 0.0Adc, @ +25°C 2. Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, @ Isat1, @ +25ºC 3. Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other heat generating components will affect the temperature rise. It is recommended that the temperature of the part not exceed 125°C under worst case operating conditions verified in the end application. 4. Isat1: Peak current for approximately 20% rolloff @ +25°C 5. Isat2: Peak current for approximately 20% rolloff @ +75°C 6. Isat3: Peak current for approximately 20% rolloff @ +100°C 7. K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L * ΔI * 10-3 Bp-p: (Gauss), K: (K-factor from table), L: (Inductance in nH), ΔI (Peak to peak ripple current in Amps). 8. Part Number Definition: FP1108Lx-Rxxx-R FP1108L = Product code and size x= Version indicator Rxxx= inductance value in μH, R= decimal point , -R suffix = RoHS compliant Dimensions (mm) Part marking: 1108Lx (x = Version indicator), Rxxx = Inductance value in uH (R= decimal point) wwllyy = date code, R = revision level All soldering surfaces to be coplanar within 0.1 millimeters PCB tolerances are ±0.1 millimeters unless otherwise specified DCR measured from point “a” to point “b” Do not route traces or vias underneath the inductor Recommended Pad Layout Schematic a b 3.50 3.15 2.45 2.4 nom 3.2 nom 3.0 nom 8.3 max 8.2 max 11.0 max |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |