| 数据搜索系统,热门电子元器件搜索 |
|
3216LV250-R 数据表(PDF) 1 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
3216LV250-R 数据表(HTML) 1 Page - Eaton All Rights Reserved. |
|
1 / 2 page ![]() Technical Data 2541 Effective May 2017 Supersedes May 2014 Product features Ordering • Specify packaging and product code (i.e., TR/3216LV1-R) 3216LV Fast-acting Line-voltage Chip™ surface mount fuse • Surface mount fuse, fast acting, 125Vac • Utilize thick and thin metal film technologies for superior fusing action and enhanced reliability. Environmental data • Operating Temperature Range: -65 °C to +125 °C, with proper derating • Thermal Shock: MIL-STD-202, Method 107, Test Condition B (-65 °C to 125 °C), 1000 cycles, fuses soldered to FR-4 glass- epoxy circuit board • Vibration: MIL-STD-202, Method 204, Test Condition C (55 Hz to 2000 HZ, 10 G) • Solderability: Withstands 60 seconds above 200 °C, 260 °C maximum • Moisture Resistance: MIL-STD-202, Method 106, 10 day cycle • Solder Leach Resistance & Terminal Adhesion: EIA-576 (30 seconds submersion in 260 °C (tin-lead solder) Soldering method • Wave Immersion: 260 °C, 10 sec max. • Infrared Reflow: 260 °C, 30 sec max. Agency information • UL Recognition Guide & File numbers: JDYX2 & E19180. • CSA Component Acceptance: 053787 C 000 & Class No: 1422 30 ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 100% 4 hours minimum 250% 5 seconds maximum SPECIFICATIONS Current Voltage Interrupting Typical Melting Integral @ 10X Rated Typ. Resistance Typ. Voltage Rating Rating Rating @ ≤ 10% Drop @ Rated Part (Amps) Vac/dc @125Vac/dc Current (A 2 * sec) Rated Current Current (Volts) Number (amps) AC DC ( ) 3216LV250-R 250mA 125 50 0.00016 0.000084 4.5 1.4 3216LV375-R 375mA 125 50 0.001 0.0002 1.80 0.73 3216LV750-R 750mA 125 50 0.0033 0.00379 0.75 0.63 3216LV1-R 1 125 50 0.020 0.0084 0.52 0.63 3216LV1.25-R 1.25 125 50 0.035 0.021 0.40 0.62 3216LV1.5-R 1.5 125 50 0.038 0.024 0.26 0.49 Notes: 1. AC interrupting rating, melting integral and total clearing integral measured at 125V, unity power factor 2. DC interrupting rating, melting integral and total clearing integral measured at 125V with a battery source 3. Voltage drop measured at 23 ± 3°C ambient temperature with the device mounted on a suitable circuit board trace 4. It is recommended that fuses be mounted with ceramic (white) side facing up 5. Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures |
类似零件编号 - 3216LV250-R |
|
类似说明 - 3216LV250-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |