| 数据搜索系统,热门电子元器件搜索 |
|
REM2 数据表(PDF) 5 Page - Recom International Power |
|
|
|||||||||||||||||||||||||||||
REM2 数据表(HTML) 5 Page - Recom International Power |
|
5 / 7 page ![]() www.recom-power.com REV.: 1/2019 MED-5 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) REM2 Series SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Medical Electric Equipment, General Requirements for Safety and Essential Performance E314885 CAN/CSA-C22.2 No. 60601-1:14, 3rd Edition, 2014 ANSI/AAMI ES60601-1 + A2:2010/®2012 Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB scheme) CB190124C12 001 IEC60601-1:2005, 3rd Edition + AM1:2012 Medical Electric Equipment, General Requirements for Safety and Essential Performance WD-SE-R-190048-A0 EN60601-1:2006 + A1:2013 Audio/Video, Information and Communication Technology Equipment - Part1: Safety Requirements WD-SE-R-180528-B0 IEC62368-1:2014, 2nd Edition EN62368-1:2014 + AC:2015 RoHS2+ RoHS-2011/65/EU + AM-2015/863 EMC Compliance Condition Standard / Criterion Medical Electrical Equipment Part 1-2: Electromagnetic Disturbances – Requirements and Tests WH-CE-E18083002 EN60601-1-2:2015 Industrial, Scientific and Medical Equipment - Radio Frequency Disturbance Characteristics - Limits and Methods of Measurement EN55011:2016 + A1:2017, Class B Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement with external filter EN55032, Class B ESD Electrostatic Discharge Immunity Test Air ±2, 4, 8, 15kV Contact ±2, 4, 6, 8kV IEC61000-4-2, Criteria A Radiated, Radio-Frequency, Electromagnetic Field Immunity Test 10V/m (80-2700MHz) 9, 27, 28V/m (several frequencies) IEC61000-4-3, Criteria A Fast Transient and Burst Immunity DC Power Port: ±0.5, 1, 2kV IEC61000-4-4, Criteria A Surge Immunity DC Power Port: ±0.5, 1kV IEC61000-4-5, Criteria B Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields DC Power Port: 3, 6V IEC61000-4-6, Criteria A Power Magnetic Field Immunity 50Hz, 30A/m IEC61000-4-8, Criteria A continued on next page -40 -20 0 20 40 70 60 -30 -10 10 30 50 80 90 95 110 100 100 80 60 40 90 70 50 30 20 10 0 Ambient Temperature [°C] Derating Graph (@ Chamber and natural convection 0.1m/s) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |