| 数据搜索系统,热门电子元器件搜索 |
|
SMB18C 数据表(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
SMB18C 数据表(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 10 page ![]() 1. Access Programming Mode. Push and hold the Limits button until the green indicator LED turns off (approximately 2 seconds). LED Indicator Status Green Turns off Amber On to indicate the sensor is ready to learn the first limit Red Flashes to indicate the strength of the echo, or it is off if no target is present 2. Set the first limit (or single set point). Place the target at the first limit and press the Limits button for less than 2 seconds. LED Indicator Status Green Remains off Amber Flashes at 2 Hz to indicate the sensor is ready to learn the second limit Red On for a moment, then resumes flashing to indicate the strength of echo 3. Set the second limit. Place the target at the second limit and press the Limits button for less than 2 seconds. LED Indicator Status Green Remains off, then turns on (returns to Run mode) Amber On for a moment, then is either on or off to indicate the output state (returns to Run mode) Red On for a moment, then resumes flashing to indicate the strength of the echo (returns to Run mode) Notes Regarding Window Limit Programming 1. Either the near or far limit may be programmed, first. 2. There is a 2-minute time-out for programming the first limit. The sensor returns to Run mode with the previously programmed limits. There is no time-out between programming of the first and second limit. 3. Cancel the programming sequence at any time by pressing and holding the button for longer than 2 seconds. The sensor returns to Run mode with the previously programmed limits. 4. If a limit is rejected during either programming step, the sensor reverts to the first limit programming step, indicated by the Green LED (off), the Red LED (flashing to indicate signal strength), and the Amber LED (on). 5. If both limits are accepted, the sensor returns to Run mode, which is indicated by the Green LED (on). 6. During limit programming, the 5-segment moving dot indicator displays the relative target position between 50 mm (2 inches) and 250 mm (the maximum recommended far limit position is 250 mm (10 inches)). 7. If the target is father than 250 mm (10 inches), the 5th segment of the moving dot indicator flashes to indicate that a valid echo is received, but the target is beyond the recommended 250 mm (10 inches) maximum far limit. 8. If the target is held at the same position for programming of both limits, the sensor establishes a 200 mm-wide sensing window, centered on the target position. U-GAGE® Q45UR Remote Ultrasonic Sensors 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 59321 Rev B |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |