| 数据搜索系统,热门电子元器件搜索 |
|
UC-R55 数据表(PDF) 3 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
UC-R55 数据表(HTML) 3 Page - Banner Engineering Corp. |
|
3 / 5 page ![]() 5. Turn potentiometer back half the number of turns from step 4. 6. Select Light Operate or Dark Operate. Specifications Supply Voltage and Current 10 V dc to 30 V dc (10% max. ripple within specified voltage range); 36 mA exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Configuration Bipolar; one current sourcing (PNP) and one current sinking (NPN) Output Rating 150 mA max. (each output) Off-state leakage current:< 10 microamps NPN saturation: < 200 mV at 10 mA and < 1.0 V at 150 mA PNP saturation: < 1 V at 10 mA and < 2.0 V at 150 mA Output Protection Circuitry Output Protection Circuitry Protected against output short-circuit, continuous overload, and false pulse on power-up Output Response Time 50 microseconds: 100 millisecond delay on power-up (outputs do not conduct) Repeatability 15 microseconds Sensing Image Rectangular: 1.2 mm × 3.8 mm (0.05 in × 0.15 in) at 10 mm (0.39 in) from face of lens; Image oriented either parallel or perpendicular to sensor length, by model (see Models on page 1). Adjustments Light/Dark Operate (LO/DO) select switch, and 15-turn switchpoint adjustment potentiometer Indicators 1 Amber: Output active 2 Green: Switchpoint threshold adjustment indicators Construction Housing: Zinc alloy die-cast housing with black painted finish and o-ring sealed lens port cap Lens: Acrylic Lens port cap and lens holder: ABS Sensitivity and LO/DO adjusters: Acetal QD: Anodized aluminum Environmental Rating IEC IP67; NEMA 6 Connections PVC-jacketed 4-conductor 2 m (6.5 ft); 9 m (30 ft) attached cable; integral 4-pin Euro-style QD fitting; or 150 mm (6 in) with 4-pin Euro-style QD fitting. Mating QD cordsets are purchased separately. Operating Conditions Temperature: −10 °C to +55 °C (+14 °F to +131 °F) Storage Temperature −20 °C to +80 °C (−4 °F to +176 °F) 90% at +50 °C maximum relative humidity (non-condensing) Vibration and Shock All models meet IEC 68-2-6 and IEC 68-2-27 testing criteria Application Notes 1. Do not mount the sensor directly perpendicular to shiny surfaces; position it at approximately 15 angle in relation to the sensing target. 2. Minimize web or product "flutter" whenever possible to maximize sensing reliability. Position sensor near a roller if possible. 3. The lens may be installed in either of the two lens ports. The lens port cap must be installed on the unused port for reliable operation. Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Certifications R58A Series Registration Mark Sensors P/N 144736 Rev. B www.bannerengineering.com - Tel: +1-763-544-3164 3 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |