| 数据搜索系统,热门电子元器件搜索 |
|
SMB30SC 数据表(PDF) 2 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
SMB30SC 数据表(HTML) 2 Page - Banner Engineering Corp. |
|
2 / 4 page ![]() Indicator and Output Behavior Sensor Conditions Indicator Output Signal Status C3 Models C4 Models Job input active Hand/pick absent On Green On Green Off Hand/pick present On Yellow On Yellow until job input is removed On No job input Hand/pick absent Off Off Off Hand/pick present On Red On Red for 5 seconds after hand/pick is removed On Note: "C3" and "C4" models as referenced in the table pertain to a part of the product model number, immediately preceding the designation. Specifications Supply Voltage 12 V dc to 30 V dc Supply Current < 75 mA max current at 12 V dc (exclusive of load) < 50 mA max current at 30 V dc (exclusive of load) Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Rating Maximum load: 150 mA ON-state saturation voltage: < 2 V dc at 10 mA; < 2.5 V dc at 150 mA OFF-state leakage current: <10 µA at 30 V dc Output Response Time 50 milliseconds On 500 milliseconds leading edge Off Power-Up Delay 300 milliseconds Indicator Lumens Color Typical Wavelength Typical Intensity (lm) Green 525 nm 29 Red 625 nm 13 Yellow 591 nm 24 Mounting M30 × 1.5 threaded base max. torque 4.5 N·m (40 in·lbf) Environmental Rating IEC IP67, IP69K per DIN 40050-9. Cabled models also meet IP69K if the cable and cable entrance are protected from high- pressure spray. Operating Conditions –40 °C to +50 °C (–40 °F to +122 °F) 90% at 50 °C maximum relative humidity (non-condensing) Storage Conditions –40 °C to +70 °C (–40 °F to +158 °F) Construction Housing: polycarbonate Translucent dome: polycarbonate Mounting nut: PBT Connections 5-pin integral M12/Euro-style QD, 2 m (6.5 ft) PVC integral cable, 5-pin 150 mm (6 in) M12/Euro-style PUR cable QD, or 5-pin 150 mm (6 in) M12/Euro-style PVC cable QD Vibration and Mechanical Shock Vibration 10 Hz to 55 Hz 1.0 mm p-p amplitude per IEC 60068-2-6 Shock 30G 11 ms duration, half sine wave per IEC 60068-2-27 Certifications Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Dimensions Standard Models Ø50 mm [1.97”] 66 mm [2.6”] 55 mm [2.17”] 35 mm [1.38”] M30 x 1.5 M12 x 1 Compact Models 17 mm [0.67”] 37.0 mm [1.46”] 48.0 mm [1.89”] Ø50 mm [1.97”] EZ-LIGHT® Touch Gen 2 K50 Specialty Pick-to-Light 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 189831 Rev. D |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |