| 数据搜索系统,热门电子元器件搜索 |
|
SMB30SC 数据表(PDF) 2 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
SMB30SC 数据表(HTML) 2 Page - Banner Engineering Corp. |
|
2 / 4 page ![]() Wiring Diagrams NPN 12-30V dc Job Light Enable < 1.0V dc – + 1 3 2 4 Load PNP 12-30V dc Job Light Enable > 7V dc – + 1 3 2 4 Load Color Key 1 = Brown 2 = White 3 = Blue 4 = Black Note: Cabled wiring diagrams are shown. Quick disconnect (QD) wiring diagrams are functionally identical. Specifications Supply Voltage 12 V to 30 V dc Supply Current < 75 mA max current at 12 V dc (exclusive of load) < 40 mA max current at 30 V dc (exclusive of load) Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Rating Maximum load: 150 mA ON-state saturation voltage: < 2 V dc at 10 mA; < 2.5 V dc at 150 mA OFF-state leakage current: <10 µA at 30 V dc Output Response Time 50 milliseconds On and Off Indicators Job ("pick") indicator: Green Pick sensed indicator: Red or Off, depending on model Indicator Lumens Color Typical Wavelength Typical Intensity (lm) Green 525 nm 29 Red 625 nm 13 Mounting M30 × 1.5 Threaded base Max torque 4.5 N·m (40 in·lbf) Operating Conditions Temperature: –40 °C to +50 °C (–40 °F to +122 °F) Humidity: 90% at 50 °C maximum relative humidity (non-condensing) Environmental Rating IEC IP67, IP69K per DIN 40050-9. Cabled models also meet IP69K if the cable and cable entrance are protected from high-pressure spray. Construction Housing: polycarbonate Translucent dome: polycarbonate Mounting nut: PBT Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements method 201A (vibration: 10 Hz to 60 Hz max., double amplitude 0.06 in. maximum acceleration 10G). Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave. Power-Up Delay 300 milliseconds Connections Integral 4-pin M12/Euro style QD, or 2 m (6.5 ft) PVC integral cable Storage –40 °C to +70 °C (–40 °F to +158 °F) Certifications Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 EZ- LIGHT® Touch K50 Series Pick to Light 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 161830 Rev. E |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |