| 数据搜索系统,热门电子元器件搜索 |
|
SMB18A 数据表(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
SMB18A 数据表(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 8 page ![]() Push Button Enable/Disable The push button can be disabled using the remote input wire (gray) to prevent unauthorized adjustment. To disable the push button, connect a normally open switch between the remote input wire and dc common or connect the remote input wire to a digital output on PLC. Perform the procedure below to enable or disable the push button. Method Action Result Remote Input3 Pulse the remote line 4-times. T T T T T T T The push button is enabled or disabled, depending on the previous condition. 2-Point Static TEACH Use 2-Point Static TEACH configuration method for applications where both ON and OFF target conditions can be presented to the sensor statically by the operator. The sensor establishes a single sensing threshold (the switchpoint) midway between the two configured conditions, with the Output ON condition on one side and the Output OFF condition on the other. Note: The sensor returns to RUN mode if the first 2-Point Static TEACH condition is not configured within 60 seconds. Note: After the first condition is configured, the sensor remains in 2-Point Static TEACH configuration until the second condition is configured. Switching Hysteresis OFF Threshold Cold Limit Hot Limit 0° C 300° C 2nd taught (Output OFF) Condition 1st taught (Output ON) Condition ON Threshold (Set at midpoint of taught conditions) When object to be sensed is hotter than ambient Switching Hysteresis OFF Threshold Cold Limit Hot Limit 0° C 300° C 1st Taught (Output ON) Condition 2nd Taught (Output OFF) Condition ON Threshold (Set at midpoint of taught conditions) When object to be sensed is colder than ambient Figure 3. 2-Point Static TEACH 1. Access 2-Point Static TEACH configuration. Method Action Result Push Button Press and hold the button for 2 seconds. • Power LED turns Red • Output LED turns Amber Remote Input2 No action required. 2. Present the output ON condition. Method Action Result Push Button Press the button 1-time. • Output LED turns OFF Remote Input Pulse the remote line 1-time. T 2 0.04 sec < T < 0.8 sec T-GAGE® M18T Series Sensor 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 120632 Rev. D |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |