| 数据搜索系统,热门电子元器件搜索 |
|
420LB28 数据表(PDF) 1 Page - Protek Devices |
|
|
|||||||||||||||||||||||||||||
420LB28 数据表(HTML) 1 Page - Protek Devices |
|
1 / 3 page ![]() 420LE28 thru 420LB60 1 05048.R3 11/03 www.protekdevices.com TWO LINE PAIR 4-20mA CONTROL LOOP PROTECTOR Only One Name Means ProTek’Tion™ APPLICATIONS ✔ Multi-Process Control Loops ✔ Fire & Security Systems ✔ Petro-Chemical Plants ✔ Refineries & Tank Farms IEC COMPATIBILITY (EN61000-4) ✔ 61000-4-2 (ESD): Air - 15kV, Contact - 8kV ✔ 61000-4-4 (EFT): 40A - 5/50ns ✔ 61000-4-5 (Surge): 8/20µs - 95A, Level 4 (Line-Gnd) & 48A, Level 4 (Line-Line) FEATURES ✔ Designed for 4-20mA Current Loops ✔ Automatic Reset - Does Not Interrupt Service ✔ Permanent Two-Stage Line Pair Protection ✔ Common Mode & Differential Mode Protection ✔ Subnanosecond Response Time ✔ Effective Against Lightning, Inductive Switching and ESD MECHANICAL CHARACTERISTICS ✔ Weight: 420LB - 28 grams & 420LE - 142 grams (Approximate) ✔ Flammability Rating UL 94V-0 ✔ Device Marking: Case - Logo, Terminal Designations & Part Number Board - Logo, Date Code & Part Number DESCRIPTION The 420LE/B series is a two stage transient voltage protector providing primary and secondary protection against lightning, inductive switching and electrostatic discharge (ESD) transient threats. The first stage diverts the transient current through the ground terminal return path and the second stage clamps the voltage to a safe level without interruption of service. The 420LE/B series is designed to protect data lines from differential (line to line) and common mode (line to ground) transients. Terminals 1 and 2, 3 and 4 for the 420LE and pins 2 and 3, 4, and 5 for the 420LB are designated as line pairs. Each line pair is referenced to ground. A transient voltage suppressor is connected across each line pair for differential mode protection. Each line pair is referenced to ground. This product can also be used on telephone, signal/data lines, security, timing and control interface circuits. For most applications, the product should be located as close as possible to the equipment being protected. A low impedance grounding system is important to maintain a low voltage clamp between the line-to-ground connection. 420LE 420LB |
类似零件编号 - 420LB28 |
|
类似说明 - 420LB28 |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |