| 数据搜索系统,热门电子元器件搜索 |
|
AHP201208FA-R24M 数据表(PDF) 3 Page - TAI-TECH Advanced Electronics Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
AHP201208FA-R24M 数据表(HTML) 3 Page - TAI-TECH Advanced Electronics Co., Ltd. |
|
3 / 6 page ![]() TAI-TECH www.tai-tech.com.tw P4 6. Reliability and Test Condition Item Performance Test Condition Operating temperature -40~+125℃ (Including self - temperature rise) Storage temperature -40~+125℃ (on board) Electrical Performance Test Inductance Refer to standard electrical characteristics list. HP4284A,CH11025,CH3302,CH1320,CH1320S LCR Meter. DCR CH16502,Agilent33420A Micro-Ohm Meter. Saturation Current (Isat) △L≦30% typical. Saturation DC Current (Isat) will cause L0 to drop △L(%)(keep quickly). Heat Rated Current (Irms) Approximately △T≦40℃ Heat Rated Current (Irms) will cause the coil temperature rise △T(℃) without core loss. 1.Applied the allowed DC current(keep 1 min.). 2.Temperature measured by digital surface thermometer Reliability Test Life Test Appearance:No damage. Inductance:within±10% of initial value Q:Shall not exceed the specification value. RDC:within ±15% of initial value and shall not exceed the specification value Preconditioning: Run through IR reflow for 2 times.( IPC/JEDEC J-STD-020DClassification Reflow Profiles) Temperature : 125±2℃(Inductor) Applied current :rated current Duration :1000±12hrs Measured at room temperature after placing for 24±2 hrs Load Humidity Preconditioning: Run through IR reflow for 2 times.( IPC/JEDEC J-STD-020DClassification Reflow Profiles Humidity :85±2﹪R.H, Temperature :85℃±2℃ Duration :1000hrs Min. with 100% rated current Measured at room temperature after placing for 24±2 hrs Moisture Resistance Preconditioning: Run through IR reflow for 2 times.( IPC/JEDEC J-STD-020DClassification Reflow Profiles 1. Baked at50℃ for 25hrs, measured at room temperature after placing for 4 hrs. 2. Raise temperature to 65±2℃ 90-100%RH in 2.5hrs, and keep 3 hours, cool down to 25℃ in 2.5hrs. 3. Raise temperature to 65±2℃ 90-100%RH in 2.5hrs, and keep 3 hours, cool down to 25℃ in 2.5hrs,keep at 25℃ for 2 hrs then keep at -10℃ for 3 hrs 4. Keep at 25℃ 80-100%RH for 15min and vibrate at the frequency of 10 to 55 Hz to 10 Hz, measure at room temperature after placing for 1~2 hrs. Thermal shock Preconditioning: Run through IR reflow for 2 times.( IPC/JEDEC J-STD-020DClassification Reflow Profiles Condition for 1 cycle Step1 :-40±2℃ 30±5min Step2 :25±2℃ ≦0.5min Step3 :125±2℃ 30±5min Number of cycles : 500 Measured at room temperature after placing for 24±2 hrs Vibration Oscillation Frequency: 10Hz~2KHz~10Hz for 20 minute Equipment: Vibration checker Total Amplitude:10g Testing Time : 12 hours(20 minutes, 12 cycles each of 3 orientations)。 Test the quantity:15pcs |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |