| 数据搜索系统,热门电子元器件搜索 |
|
VCTA25201B-R10MS6 数据表(PDF) 3 Page - Cyntec Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
VCTA25201B-R10MS6 数据表(HTML) 3 Page - Cyntec Co., Ltd. |
|
3 / 8 page ![]() CYNTEC CO., LTD. 乾坤科技股份有限公司 Oct., 2019 DOCUMENT : CYNVC-175-021 REVISION : A8 PAGE : 3 OF 8 Marking The point on the top surface represents winding direction of choke. Coil clockwise around Upside of Chip PIN 2 PIN 1 Specifications Part Number L0 ◇ Inductance ( H ) @ (0A) Rdc ( m) ◇ Heat Rating Current DC Amps. Idc ( A ) Saturation Current DC Amps. Isat ( A ) Rated voltage (V) Typical Maximum Typical Maximum Typical Maximum Maximum VCTA25201B-R10MS6 0.10 9.0 11.0 7.7 7.0 12.8 11.0 20 VCTA25201B-R33MS6 0.33 16.0 20.0 5.4 4.8 7.5 6.4 20 VCTA25201B-R47MS6 0.47 21.0 26.0 4.7 4.0 6.5 5.6 20 VCTA25201B-1R0MS6 1.0 35.0 42.0 3.8 3.4 4.8 4.2 20 VCTA25201B-1R5MS6 1.5 50.0 60.0 3.1 2.7 3.9 3.3 20 VCTA25201B-2R2MS6 2.2 70.0 84.0 2.6 2.2 3.5 3.0 20 VCTA25201B-3R3MS6 3.3 115.0 140.0 2.0 1.8 2.7 2.3 20 VCTA25201B-4R7MS6 4.7 165.0 200.0 1.7 1.4 22 2.2 2.0 20 VCTA25201B-6R8MS6 6.8 330.0 400.0 1.2 1.0 1.8 1.6 20 VCTA25201B-100MS6 10.0 440.0 530.0 1.0 0.8 1.5 1.3 20 ◇: Significant Characteristic * :If you require another part number please contact with us. **:Inductance Tolerance 20% Note 1.: All test data is referenced to 25℃ ambient. Note 2.: Test Condition:1MHz, 1.0Vrms Note 3.: Idc : DC current (A) that will cause an approximate △T of 40℃ Note 4.: Isat : DC current (A) that will cause L0 to drop approximately 30% Note 5.: Operating Temperature Range -55℃ to + 165℃ Note 6.: The part temperature (ambient + temp rise) should not exceed 165℃ under the worst case operating conditions. Circuit design, component placement, PCB trace size and thickness, airflow and other cooling provision all affect the part temperature. Part temperature should be verified in the end application. Note 7.: The rated current as listed is either the saturation current or the heating current depending on which value is lower. Note 8.: Cleaning Process Note (a) If this power choke is dipped in the cleaning agent, such as toluene, xylene, ketone, and ether system, there is a possibility that the performance decreases greatly (b) The high power ultrasonic washing may damage the choke body. (c) Please contact us if you need the cleaning via the above agents or ultrasonic washing. Issued |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |