13 / 16 page ![]() 13 SEL Data Bit Baud Rate Parity Bit Print Options Meter Address Abbreviated Printing 5-SEriAL bAUd dAtA PAritY Addr Abbr Prnt OPt Copy Program Settings COPY Pro 6.5 Module 5 - Serial coMMunicationS paraMeterS (5-SEriAL) PARAMETER MENU DATA BIT ABBREVIATED PRINTING PRINT OPTIONS PARITY BIT METER ADDRESS The Serial Setup Parameters are only active when one of the optional serial communication/programming cards is installed in the meter. Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements. This section replaces the bulletin shipped with the RS232 and RS485 serial communications plug-in cards. Discard the separate bulletin when using those serial plug-in cards with the CUB5B and CUB5R. BAUD RATE Set the baud rate to match that of other serial communications equipment. Normally, the baud rate is set to the highest value that all of the serial communications equipment is capable of transmitting and receiving. Select either 7- or 8-bit data word length. Set the word length to match the other serial communications equipment on the serial link. This parameter only appears when the Data Bit parameter is set to a 7-bit data word length. Set the parity bit to match that of the other serial equipment on the serial link. The meter ignores parity when receiving data and sets the parity bit for outgoing data. If parity is set to NO, an additional stop bit is used to force the frame size to 10 bits. Enter the serial node address. With a single unit, an address is not needed and a value of zero can be used (RS232 applications). Otherwise, with multiple bussed units, a unique address number must be assigned to each meter. The node address applies specifically to RS485 applications. This parameter determines the formatting of data transmitted from the meter in response to a Transmit Value command or a Block Print Request. Select NO for a full print transmission, consisting of the meter address, mnemonics, and parameter data. Select YES for abbreviated print transmissions, consisting of the parameter data only. This setting is applied to all the parameters selected in the PRINT OPTIONS. (Note: If the meter address is 0, the address will not be sent during a full transmission.) This parameter selects the meter values transmitted in response to a Print Request. A print request is also referred to as a block print because more than one parameter can be sent to a printer or computer as a block. Selecting YES displays a sublist for choosing the meter parameters to appear in the print block. All active parameters entered as YES in the sublist will be transmitted during a block print. Parameters entered as NO will not be sent. The “Print All” (Prnt ALL) option selects all meter values for transmitting (YES), without having to individually select each parameter in the sublist. Note: Inactive parameters will not be sent regardless of the print option setting. For example, Counter B or Scale Factor B will only be sent if Counter B is enabled (Dual Counter mode or batch count). Likewise, the Setpoint value(s) will not be sent unless an optional setpoint card is installed in the meter. DISPLAY DESCRIPTION FACTORY SETTING MNEMONIC Count A Counter A YES CTA Count b Counter B NO CTB RAtE Rate Value NO RTE CntA ScF Scale Factor A NO SFA Cntb ScF Scale Factor B NO SFB sSP1 Setpoint 1 NO SP1 SP2 Setpoint 2 NO SP2 CntA Ld Counter A Count Load NO CLD 9600 bAUd 7-bit dAtA Odd PAritY 00 Addr NO Abbr NO Prnt OPt 0 to 99 9600 4800 38400 19200 2400 600 1200 300 8-bit 7-bit EVEN Odd NO YES NO YES NO NO COPY COPY PROGRAM SETTINGS NO YES This parameter is used to copy all the program settings from one CUB5 meter directly to another CUB5 meter, through the serial communications cards (RS232 or RS485). The USB programming card cannot be used for the copy procedure. No PC connection or additional software is required. Copying program settings eliminates the need for repetitive programming when multiple meters use identical settings. Copy Requirements: To copy program settings from one meter to another requires the following: 1. Both meters must have the same software version (Version 3.1 or later). The version is displayed during the meter power-up sequence, or in Module 3 at the Software Version Display parameter. (See Module 3 for details) 2. The meter receiving the program settings (receiver) must have the Baud Rate set to 9600 baud. Since this is the factory default setting, a new meter will arrive ready for copying. The meter sending the program settings (master) should be set to the desired Baud Rate for the application (if different than 9600). This Baud Rate setting will then be copied to the receiver. Copy Connections: To connect the meters for copying, install a serial communications card of the same type into each meter (RS232 or RS485). Connect the meters using the proper cable listed in the chart. TYPE DESCRIPTION PART NUMBER RS232 CBLRLC02 RS485 CBLRLCS2 Copy Cable RS232 10’ (RJ12-RJ12) Copy Cable RS485 10’ (RJ12-RJ12) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |