| 数据搜索系统,热门电子元器件搜索 |
|
MLPS 数据表(PDF) 2 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
MLPS 数据表(HTML) 2 Page - Red Lion Controls. Inc |
|
2 / 16 page ![]() 1. DISPLAY: 8 digit LCD 0.46" (11.7 mm) high digits CUB5R000: Reflective LCD with full viewing angle CUB5B000: Transmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module. 2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input polarity protection. Must use an RLC model MLPS or an NEC Class 2 or Limited Power Source (LPS) rated power supply. MODEL NO. DISPLAY COLOR INPUT CURRENT @ 9 VDC WITHOUT CUB5RLY0 INPUT CURRENT @ 9 VDC WITH CUB5RLY0 CUB5R000 --- 10 mA 30 mA CUB5B000 Red (max intensity) 85 mA 115 mA CUB5B000 Green (max intensity) 95 mA 125 mA 3. COUNTER DISPLAYS: Counter A: 8-digits, enabled in all count modes Display Range: -9999999 to 99999999 Overflow Indication: Display flashes “Cnt OVEr” Counter B: 7-digits, enabled in Dual Counter Mode or batch counting Display Designator: “b” to the left side of the display Display Range: 0 to 9999999 (positive count only) Overflow Indication: Display flashes “bCntOVEr” Maximum Count Rates: 50% duty cycle Without setpoint option card: 20 KHz (all count modes) With setpoint option card: 20 KHz for any count mode except Dual Counter (16 KHz), Quadrature x2 (14 KHz) and Quadrature x4 (13 KHz). 4. RATE DISPLAY: 6-digits, may be enabled or disabled in any count mode Display Designator: “R” to the left side of the display Display Range: 0 to 999999 Over Range Display: “R OLOLOL” Maximum Frequency: 20 KHz Minimum Frequency: 0.01 Hz Accuracy: ±0.01% 5. COUNT/RATE SIGNAL INPUTS (INP A and INP B): Input A: DIP switch selectable to accept pulses from a variety of sources. See Section 2.0 Setting the DIP Switches for Input A specifications. Input B: Logic signals only Trigger levels: VIL = 0.7 V max; VIH = 2.4 V min; VMAX = 28 VDC Current sinking: Internal 10KΩ pull-up resistor to +9 to 28 VDC Filter (LO Freq.): Damping capacitor provided for switch contact bounce. Limits input frequency to 50 Hz and input pulse widths to 10 msec min. 6. USER INPUT (USR): Programmable input. Connect to input common (INP COMM) to activate function. Internal 10KΩ pull-up resistor to +9 to 28 VDC. Threshold Levels: VIL = 0.7 V max; VIH = 2.4 V min; VMAX = 28 VDC Response Time: 5 msec typ.; 50 msec debounce (activation and release) 7. MEMORY: Nonvolatile E2PROM memory retains all programming parameters and count values when power is removed. 8. CONNECTIONS: Wire clamping screw terminals Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 3.5 inch-lbs (0.395 N-m) max. 9. CONSTRUCTION: This unit rated for Type 4X/IP65 requirements for indoor/ outdoor use. Installation Category I, Pollution Degree 2. High impact plastic case with clear viewing window. Panel gasket and mounting clip included. 10. ENVIRONMENTAL CONDITIONS: Operating Temperature Range for CUB5R000: -35 to 75 °C Operating Temperature Range for CUB5B000 depends on display color and intensity level as per below: INTENSITY LEVEL TEMPERATURE Red Display 1 & 2 -35 to 75°C 3 -35 to 70°C 4 -35 to 60°C 5 -35 to 50°C Green Display 1 & 2 -35 to 75°C 3 -35 to 65°C 4 -35 to 50°C 5 -35 to 35°C Storage Temperature: -35 to 85 °C Operating and Storage Humidity: 0 to 85% max. relative humidity (non- condensing) Vibration to IEC 68-2-6: Operational 5-500 Hz, 5 g Shock to IEC 68-2-27: Operational 40 g Altitude: Up to 2000 meters 11. CERTIFICATIONS AND COMPLIANCES: CE Approved EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A Safety requirements for electrical equipment for measurement, control, and laboratory use: EN 61010-1: General Requirements EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits RoHS Compliant UL Recognized Component: File #E179259 UL Listed: File #E137808 Type 4X Indoor/Outdoor Enclosure rating (Face only) IP65 Enclosure rating (Face only) IP20 Enclosure rating (Rear of unit) Refer to EMC Installation Guidelines for additional information. 12. WEIGHT: 3.2 oz (100 g) 2 General Meter SpecificationS orderinG inforMation TYPE MODEL NO. DESCRIPTION PART NUMBER CUB5 CUB5R Dual Counter & Rate Indicator with Reflective Display CUB5R000 CUB5B Dual Counter & Rate Indicator with Backlight Display CUB5B000 Optional Plug-in Cards CUB5RLY Single Relay Option Card CUB5RLY0 CUB5SNK Dual Sinking Open Collector Output card CUB5SNK0 CUB5COM RS485 Serial Communications Card CUB5COM1 RS232 Serial Communications Card CUB5COM2 CUB5USB USB Programming Card CUB5USB0 Accessories MLPS +12 VDC Micro-Line Power Supply, 85 to 250 VAC source, 400 mA max out MLPS1000 +24 VDC Micro-Line Power Supply, 85 to 250 VAC source, 200 mA max out MLPS2000 CBLPRO Programming Cable RS232 (RJ11-DB9) CBLPROG0 CBPRO Communication Cable RS485 (RJ11-DB9) CBPRO007 SFCRD Crimson PC Configuration Software, Free Download Available1 SFCRD200 CBLUSB USB Programming Cable CBLUSB00 1 Crimson software is a free download from http://www.redlion.net. System requirements for the software are listed on the download page. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |