| 数据搜索系统,热门电子元器件搜索 |
|
STEVAL-XPLM01CPL 数据表(PDF) 2 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STEVAL-XPLM01CPL 数据表(HTML) 2 Page - STMicroelectronics |
|
2 / 4 page ![]() Schematic diagram STEVAL-XPLM01CPL 2/4 DocID030653 Rev 1 1 Schematic diagram Figure 1: STEVAL-XPLM01CPL circuit schematic IMPORTANT – Safety recommendations The STEVAL-XPLM01CPL must be used by expert technicians only. Due to the high voltage (85 - 265 Vac) present on the non-isolated parts, special care must be taken in order to avoid electric risks for people safety. There are no protections against high voltage accidental human contact. After disconnection of the board from the mains, no live part can be touched immediately because of the energized capacitor. Do not connect any instrument probe to high voltage parts if the board is not isolated from the mains supply, in order to avoid damaging any equipment. ST assumes no responsibility for the consequences of any improper use of this development tool. SIGNAL N P D1 SM6T15CA F1 4A - T SIOV1 S14K320/EPC CN1 SIGNAL_CONNECTOR 2 1 L1 4.7µH J1 MAINS_CONNECTOR 2 1 C2 470nF X2 C1 10µF T1 TDK SRW13EP-X05H002 / WE 750-510-231 1 4 10 7 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|