18 / 40 page ![]() This kind of operation, together with the extremely low IC quiescent current, allows very low input power consumption in no-load and light load, while the low DRAIN peak current value, IDLIM_PFM, prevents any audible noise which could arise from low switching frequency values. When the output load is increased, VCOMP increases and PFM is exited. VCOMP reaches its maximum at VCOMPH, corresponding to the DRAIN current limitation (IDLIM). 4.11 Overload protection In order to manage the overload condition the IC embeds the following main blocks: the OCP comparator to turn off the power MOSFET when the drain current reaches its limit (IDLIM), the up and down OCP counter to define the turn-off delay time in case of continuous overload (tOVL = 50 ms typ.) and the timer to define the restart time after protection tripping (tRESTART = 1 sec, typ.). In case of short-circuit or overload, the control level on the inverting input of the PWM comparator is greater than the reference level fed into the inverting input of the OCP comparator. As a result, the cycle-by-cycle turn off of the power switch is triggered by the OCP comparator instead of by the PWM comparator. Every cycle this condition is met, the OCP counter is incremented. If the fault condition persists for a time greater than tOVL (corresponding to the counter end-of-count), the protection is tripped, the PWM is disabled for tRESTART, then it resumes switching with soft-start and, if the fault is still present, it is disabled again after tOVL. The OLP management prevents the IC from being indefinitely operated at IDLIM and the low repetition rate of the restart attempts of the converter avoids overheating the IC in case of repeated fault events. After the fault removal, the IC resumes working normally. If the fault is removed before the protection tripping (before tOVL), the tOVL counter is decremented on a cycle-by-cycle basis down to zero and the protection is not tripped. If the fault is removed during tRESTART, the IC waits for the tRESTART period ot have elapsed before resuming switching. In fault condition, VCC is kept between VCSon and VCCon by the periodical activation of the HV current source, which recharges the VCC capacitor to VCcon any time the IC internal consumption discharges it to VCson. Figure 28. Overload protection time VCC VCCon VCSon IDRAIN IDLIM tOVL tRESTART tSS tOVL Overload applied tSS time Overload removed tRESTART 4.12 Undervoltage protection If the voltage across the UVP pin (VUVP) falls below the internal threshold VUVP_th (0.4 V typ.) for a time greater than tUVP_DEB (30 ms, typ.), the IC is disabled and its consumption is reduced to ultra-low values (Iq_DIS). When VUVP rises above VUVP_th, the IC must wait tUVP_REST (30 ms, typ.) before resuming switching. Both tUVP_DEB and tUVP_REST are intended to filter out possible noises/disturbances of the line, which could affect the correct operation of the function. They are obtained through two separate up/down counters: DEB (REST) up/down counter has a deb_eoc (rest_eoc) end-of-count. The operation is illustrated in Figure 29. UVP timing. If the counter starts from zero and counts always up, end-of-count is reached in a time interval tUVP_DEB (tUVP_REST). VIPER31 Overload protection DS13285 - Rev 3 page 18/40 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |