| 数据搜索系统,热门电子元器件搜索 |
|
DMB01DM24. 数据表(PDF) 2 Page - Carlo Gavazzi Holding AG |
|
|
|||||||||||||||||||||||||||||
DMB01DM24. 数据表(HTML) 2 Page - Carlo Gavazzi Holding AG |
|
2 / 4 page ![]() 2 Specifications are subject to change without notice (18.06.07) DMB01, PMB01 Function Op Delay on operate The time period begins as soon as the trigger contact is closed. At the end of the set delay time the relay operates and doesn't release until the trig- ger contact is closed again or the power supply is dis- connected. If the trigger contact is closed before the end of the delay time, the device resets and a new time period starts. Function In Interval The relay operates and the time period begins as soon as the trigger contact is closed. The relay releases at the end of this period or when the power supply is disconnected. The relay operates again when the trigger contact is closed again. If the trigger contact is closed before the end of the delay time, the relay keeps ON and a new time period starts. Function Io Interval on trigger open The relay operates and the time period begins as soon as the trigger contact is opened. At the end of the set delay or when the power supply is disconnected the relay releases. The relay operates again when the trigger contact is opened again. If the trigger contact is opened before the end of the delay time the relay keeps ON and a new time period begins. Function Id Double interval The relay operates and the time period begins as soon as the trigger contact is closed. The relay releases at the end of this period or when the power supply is disconnected. When the trigger contact is opened the relay operates again for the set delay period. If the trigger contact is opened before the end of the first time period the second one begins; if the trigger contact is closed before the end of the second time period the relay keeps ON and the first time period begins again. Function Dr Delay on release The relay operates as soon as the trigger contact is closed. The time period begins when the trigger con- tact is opened. The relay releases at the end of the set delay time or when the power supply is disconnect- ed. The relay operates again when the input contact is closed again. If it is closed before the end of the delay time the relay keeps ON, a new time period begins as soon as the contact is opened again. Function R Symmetrical recycler, ON- time period first The relay operates and the time period begins as soon as the input contact is closed. After the set delay period the relay releases for the same time period. This sequence continues with equal ON- and OFF-time periods until the power sup- ply is interrupted. Function Rb Symmetrical recycler, OFF-time period first The time period begins as soon as the input contact is closed. The relay is OFF during the set delay period, after this time it operates for the same time period. This sequence continues with equal OFF- and ON-time periods until power supply is interrupted. Supply Specifications General Specifications Function and Time Setting Mode of Operation Power supply Overvoltage cat. III Rated operational voltage (IEC 60664, IEC 60038) through terminals: (DMB01C) A1, A2 24 VDC ±15% and (PMB01C) 2, 10 24 to 240 VAC +10%/-15%, 45 to 65 Hz (DMB01D) A1, A2 24 to 240 VAC/DC (PMB01D) 2, 10 +10%/-15%, 45 to 65 Hz Voltage interruption ≤ 10 ms Rated operational power AC supply 4 VA DC supply 1.5 W Power ON delay ≤ 100 ms Indication for Power supply ON LED, green Output relays ON LED, yellow (flashing when timing) Environment (EN 60529) Degree of protection IP 20 Pollution degree 3 (DMB01), 2 (PMB01) (IEC 60664) Operating temperature -20 to 60°C, R.H. < 95% Storage temperature -30 to 80°C, R.H. < 95% Housing Dimensions DMB01 22.5 x 80 x 99.5 mm PMB01 36 x 80 x 94 mm Weight Approx. 130 g Screw terminals Tightening torque Max. 0.5 Nm according to IEC EN 60947 Approvals UL, CSA RINA (DMB01 only) CE Marking Yes EMC Electromagnetic Compatibility Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Timer Specifications According to EN 61812-1 Upper knob: Setting of function: Op - delay on operate In - interval Io - interval on trigger open Id - double interval Dr - delay on release R - symmetrical recycler (ON first) Rb - symmetrical recycler (OFF first) Centre knob: Time setting on relative scale: 1 to 10 with respect to the chosen range. Lower knob: Setting of time range. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |