2 / 3 page ![]() 2 Specifications are subject to change without notice (14.04.20) DBB02, PBB02 General Specifications Power ON delay ≤ 200 ms Power OFF delay ≤ 100 ms Indication for Power supply ON LED, green Environment (EN 60529) Degree of protection IP 20 Pollution degree 3 (DBB02), 2 (PBB02) (IEC 60664) Operating temperature up to 265 VAC, 135 VDC 0 to 60 °C, R.H. < 95% from 135 VDC @5A 0 to 45 °C, R.H. < 95% Storage temperature -30 to 80 °C, R.H. < 95% Mode of Operation Range/Time Setting Adjust the time range set- ting the DIP-switches 1 and 2 as shown below. To access the DIP-switches open the plastic cover using a screwdriver as shown below. Centre knob: Time setting on relative scale: 1 to 10 with respect to the chosen range. Operation Diagram Time range ON OFF ON ON: 60 to 600 s ON ON OFF OFF: 0.1 to 1 h OFF OFF OFF ON: 1 to 10 h ON OFF Housing Dimensions DBB02 22.5 x 80 x 99.5 mm PBB02 36 x 80 x 94 mm Weight Approx 130 g Screw terminals (DBB02) Tightening torque Max 0.5 Nm according to IEC EN 60947 Approval UL, CSA CE Mark Yes EMC Electromagnetic Compatibility Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Timer Specifications According to EN 61812-1 The relay(s) operates as soon as the power supply is applied. When the power supply is interrupted the time period starts and, at the expiration of the set time period, the relay releases. If the power supply is reapplied before the relay released the time is reset and the relay remains ON. The built-in non-replace- able battery (Ni-MH) will be charged while the power supply is applied. Note: DBB02 and PBB02 should not be operated by pulses shorter than 200 ms. For these purposes the relays DMB01 or PMB01, operated by external contact function, should be used. The battery test is per- formed on terminals + and A2 or 7 and 10. It is recommended to con- nect DBB02 and PBB02 to the power supply for 42 h before it is put into regular service in order to compen- sate for energy losses due to, for example, a long stor- age period. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |