2 / 6 page ![]() 2 Specifications are subject to change without notice (18.06.07) DMC01, PMC01 Supply Specifications General Specifications Power supply Overvoltage cat. III Rated operational voltage (IEC 60664, IEC 60038) through terminals: A1, A2 or A1, A3 (DMC01) B48 24 or 48 VAC ± 15% 45 to 65 Hz B23 115 or 230 VAC ± 15% 45 to 65 Hz 724 24 VDC ± 20% 2, 10 (PMC01) 024 24 VAC ± 15%,45 to 65 Hz 115 115 VAC ± 15%,45 to 65 Hz 230 230 VAC ± 15%,45 to 65 Hz 724 24 VDC ± 20% Voltage interruption ≤ 10 ms Rated operational power AC supply: 5 VA DC supply: 2 W Power ON delay ≤ 100 ms Reaction time from trigger Delayed contact(s) < 10 ms Instantaneous contcat < 20 ms Indication for Power supply ON LED, green Output relays ON LED, yellow (flashing when timing) Environment (EN 60529) Degree of protection IP 20 Pollution degree 3 (DMC01), 2 (PMC01) (IEC 60664) Operating temperature -20 to 60 °C, R.H. < 95% Storage temperature -30 to 80 °C, R.H. < 95% Housing Dimensions DMC01C 22.5 x 80 x 99.5 mm DMC01D 45 x 80 x 99.5 mm PMC01 36 x 80 x 94 mm Weight 120 to 260g depending on model Screw terminals (DMC01) Tightening torque Max 0.5 Nm according to IEC EN 60947 Approval UL, CSA CE Marking Yes EMC Electromagnetic Compatibility Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Timer Specifications According to EN 61812-1 Function/Range/Time Setting Adjust the function setting the DIP switches 1 to 6 as shown below (1 to 4 for DMC01Cxxx). Note 1: DIP switch 5 must be kept ON when using PMC01Dxxx. Note 2: DIP switch 6 does not have any effect on the PMC01Cxxx working mode. To access the DIP switches open the grey plastic cover using a screwdriver as shown below. Upper knob: Selection of function: Op - Delay on operate, manual start Oa - Delay on operate, automatic and manual start In - Interval, manual start Ia - Interval, automatic and manual start Nr - Interval with no time reset, manual start Na - Interval with no time reset, automatic and manual start Dr - Delay on release Centre knob: Time setting on relative scale: 1 to 10 with respect to the chosen range. Lower knob: Setting of time range External potentiometer (DMC01D, PMC01C): Time setting on relative scale: 1 to 10 with respect to the chosen range. Output Specifications Output 1 or 2 x SPDT relay Rated insulation voltage 250 VAC (RMS) Contact Ratings (AgSnO2)µ Resistive loads AC 1 8 A @ 250 VAC DC 12 5 A @ 24 VDC Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC Mechanical life ≥ 30 x 106 operations Electrical life ≥ 105 operations (at 8 A, 250 V, cos ϕ = 1) Operating frequency < 7200 operations / h Dielectric strength Dielectric voltage 2 kVAC (RMS) Rated impulse withstand volt. 4 kV (1.2/50 µs) Sensor type selection ON ON OFF OFF: PNP/NPN sensor, Open collector or contact OFF OFF ON ON: Namur sensor Time setting (DMC01D and PMC01C) ON: Centre knob on front OFF: External trimmer Second relay ON: Instantaneous OFF: DPDT DMC01D, PMC01C, PMC01D DMC01C |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |