| 数据搜索系统,热门电子元器件搜索 |
|
M2EXS 数据表(PDF) 4 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M2EXS 数据表(HTML) 4 Page - M-System Co.,Ltd. |
|
4 / 5 page ![]() MODEL: M2EXS M2EXS SPECIFICATIONS ES-5137 Rev.4 Page 4/5 http://www.m-system.co.jp/ PARAMETER LIST It is available to con gure or con rm settings shown below by using front button. Con guring or con rming with PC is available when using M2E con gurator software (model: M2ECFG). MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL VALUE Basic setting 01 Lockout setting Lock / Unlock — Lock 06 Angle offset — Deg. 0.00 07 Angle span 60.00 – 359.99 Deg. 270.00 10 Rotating direction CW / CCW — CW 14 0 % input scaling -99999 – 999999 — 0.00 15 100 % input scaling -99999 – 999999 — 100.00 16 Input decimal point No decimal point The number of decimal places : 1 – 5 — 2 places of decimals 17 Output range 0 – 20 mA -5 – +5 V -10 – +10 V — 0 – 20 mA 18 0 % output setting 0.000 – 19.000 -5.000 – 4.750 -10.000 – 9.000 mA V V 4.000 19 100 % output setting 1.000 – 20.000 -4.750 – 5.000 -9.000 – 10.000 mA V V 20.000 20 0 % output scaling -99999 – 999999 — 0.00 21 100 % output scaling -99999 – 999999 — 100.00 22 Output decimal point No decimal point The number of decimal places : 1 – 5 — 2 places of decimals 23 Overrange output < 0% -5.00 – 0.00 % -5.00 24 Overrange output > 100% 100.00 – 105.00 % 105.00 26 Loop test -5.00 – 105.00 % Cancel Option 60 Unit (INP Scaling) Choose from 68 types * — % 61 Unit (OUT Scaling) Choose from 68 types * — % 67 Filter time constant 0 – 30 sec. 0 71 Output Zero ne adjust -5.000 – 5.000 % 0.000 72 Output Span ne adjust 95.000 – 105.000 % 100.000 01 Lockout setting Lock / Unlock — Lock Advanced 90 Display setting Upper: choose from 5 types * Lower: choose from 6 types * — Upper: INPUT Lower: PERCENT 91 Brightness 1 (darkest) – 4 (brightest) — 4 92 Display timeout 0 (always on), 1 – 60 min. 10 93 Reset all settings OFF / RESET — OFF 94 Version indication — — — 01 Lockout setting Lock / Unlock — Lock Linearization 100 User's table linearization Disable / Enable — Disable 101 Number of points 2 – 32 — 2 102 – 165 Table -5.00 – 105.00 % X001 -5.00 Y001 -5.00 X002 105.00 Y002 105.00 01 Lockout setting Lock / Unlock — Lock * For detailed types, refer to the operating manual (EM-5137-B). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |