| 数据搜索系统,热门电子元器件搜索 |
|
M2EXM-R 数据表(PDF) 4 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M2EXM-R 数据表(HTML) 4 Page - M-System Co.,Ltd. |
|
4 / 5 page ![]() MODEL: M2EXM M2EXM SPECIFICATIONS ES-5135 Rev.4 Page 4/5 http://www.m-system.co.jp/ PARAMETER LIST It is available to con gure or con rm settings shown below by using front button. Con guring or con rming with PC is available when using M2E con gurator software (model: M2ECFG). MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL VALUE Basic setting 01 Lockout setting Lock / Unlock — Lock 12 0 % input setting — — 0 13 100 % input setting — — 10000 14 0 % input scaling -99999 – 999999 — 0.00 15 100 % input scaling -99999 – 999999 — 100.00 16 Input decimal point No decimal point The number of decimal places : 1 – 5 — 2 places of decimals 17 Output range 0 – 20 mA -5 – +5 V -10 – +10 V — 0 – 20 mA 18 0 % output setting 0.000 – 19.000 -5.000 – 4.750 -10.000 – 9.000 mA V V 4.000 19 100 % output setting 1.000 – 20.000 -4.750 – 5.000 -9.000 – 10.000 mA V V 20.000 20 0 % output scaling -99999 – 999999 — 0.00 21 100 % output scaling -99999 – 999999 — 100.00 22 Output decimal point No decimal point The number of decimal places : 1 – 5 — 2 places of decimals 26 Loop test -5.00 – 105.00 % Cancel Option 60 Unit (INP Scaling) Choose from 68 types* — % 61 Unit (OUT Scaling) Choose from 68 types* — % 67 Filter time constant 0 – 30 sec. 0 69 Input Zero ne adjust -5.000 – 5.000 % 0.000 70 Input Span ne adjust 95.000 – 105.000 % 100.000 71 Output Zero ne adjust -5.000 – 5.000 % 0.000 72 Output Span ne adjust 95.000 – 105.000 % 100.000 01 Lockout setting Lock / Unlock — Lock Advanced 90 Display setting Upper: choose from 5 types* Lower: choose from 6 types* — Upper: INPUT Lower: PERCENT 91 Brightness 1 (darkest) – 4 (brightest) — 4 92 Display timeout 0 (always on), 1 – 60 min. 10 93 Reset all settings OFF / RESET — OFF 94 Version indication — — — 01 Lockout setting Lock / Unlock — Lock Linearization 100 User's table linearization Disable / Enable — Disable 166 Number of points 2 – 111 — 2 167 – 388 Table -5.00 – 105.00 % X001 -5.00 Y001 -5.00 X002 105.00 Y002 105.00 01 Lockout setting Lock / Unlock — Lock * For detailed types, refer to the operating manual (EM-5135-B). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |