| 数据搜索系统,热门电子元器件搜索 |
|
ASW2 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
ASW2 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: ASW2 ASW2 SPECIFICATIONS ES-1618 Rev.8 Page 2/4 https://www.m-system.co.jp/ Isolation: Input to output to power Setpoint adjustments: Multi-turn screwdriver adjustments (front); 0 – 100% independently Monitor jacks: Output 0 – 10 V for 0 – 100 % setpoints Monitor jack diameter: 2 mm (.08") Hysteresis (deadband): 0.5 – 1.0 % Front LEDs: Red LED turns on when the coil is energized. Power ON timer: Relays de-energized for approx. 2 seconds after power is turned on. INPUT SPECIFICATIONS ■ DC Current: Shunt resistor attached to the input terminals (0.5 W) Specify input resistance value for code Z. ■ DC Voltage: -30 – +30 V DC Span: Min. 50 mV, Max. 30 V Offset: Max. 1.5 times span Input resistance Span 50 – 100 mV : ≥ 10 kΩ Span 0.1 – 1 V : ≥ 100 kΩ Span ≥ 1 V : ≥ 1 MΩ OUTPUT SPECIFICATIONS ■ Relay Contact: 120 V AC @ 0.5 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 0.5 A (resistive load) Maximum switching voltage: 380 V AC or 125 V DC Maximum switching power: 120 VA or 30 W (≤ 0.5 A) Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles For maximum relay life with inductive loads, external protection is recommended. Alarm Trip Operation Terminal No. in parentheses Trip Operation in Power Failure : Terminals 1 – 2, 9 – 10 turn ON. 0 50 100 Input (%) Lo Setpoint Hi Setpoint Hi Output (9–15)ON Lo Output (1–2)ON (1–11)ON (9–10)ON INSTALLATION Power input • AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz, approx. 2 VA •DC: Operational voltage range: rating ±10 %, ripple 10 %p-p max., approx. 2 W (80 mA at 24 V) Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lb) PERFORMANCE in percentage of span Setpoint monitor accuracy: ± 0.5 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2300 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (output) Installation Category II (power) Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) (When 150 V AC max. load voltage or measurement category I, applicable as reinforced insulation) RoHS Directive |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |