| 数据搜索系统,热门电子元器件搜索 |
|
AS4LC 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
AS4LC 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: AS4LC AS4LC SPECIFICATIONS ES-1601 Rev.13 Page 2/4 https://www.m-system.co.jp/ • Others (Refer to the instruction manual) ■ DISPLAY LED: 8 mm (.31”) 7 segment, red Number of display digits: 4 digits for DATA display; 2 digits for ITEM display Range: -1999 to 9999 (decimal point position selectable) PV indication: Input signal in engineering unit Overrange indication: LEDs blinking Power saving mode: Displays turn off if the keys are untouched for a preset time period LEDs: Red LEDs turn on when coils are energized. (PL1 and PL2 for 2-point alarm. PL1, PL2, PL3 and PL4 for 4- point alarm.) INPUT SPECIFICATIONS ■ Strain Gauge Input • Strain Gauge Sensor sensitivity setting S1: 0.010 - 3.000mV/V S2: 0.010 - 9.999mV/V S3: 0.10 - 30.00mV/V Sensor sensitivity setting min. step: S1: 0.001 mV/V S2: 0.001 mV/V S3: 0.01 mV/V Default setting: S1: 3.000 mV/V S2: 9.999 mV/V S3: 30.00 mV/V Rated output from strain gauge: S1: -30.00 – +30.00 mV, span 1.00 – 30.00 mV S2: -99.99 – +99.99 mV, span 3.00 – 99.99 mV S3: -300.0 – +300.0 mV, span 10.0 – 300.0 mV Input voltage setting min. step: S1: 0.01 mV S2: 0.01 mV S3: 0.1 mV Note: Consult factory for use with a compression/tension load cells. • Excitation: 0.1 – 12.0 V adjustable (0.1 V increments) Maximum current: 30 mA Default setting: 1.0 V ■ Contact Input: TTL level (5V-CMOS level), open collector or dry contact (detecting voltage: approx. 5 V, saturation voltage: ≤ 1 V, sink current: 0.5 mA) OUTPUT SPECIFICATIONS Relay rating: 120 V AC @ 1 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) (Limited within 0.5 A to conform with EU Directive) Maximum switching voltage: 380 V AC or 125 V DC Maximum switching power: 120 VA or 30 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles 0 50 100 ▲ Input (%) LL L ▲ ▲ HH H L2 (15–8) ON ▲ L3 (10–8) ON L4 (1–8) ON OFF OFF L1 (9–8) ON OFF OFF Alarm Trip Operation Terminal No. in parentheses Example with quad N.O. contacts (LL, L, H, HH) Trip Operation in Power Failure • Output code 2: All relays turn off. • Output code 3: All relays turn on. • Output code 5: Terminals 15 – 8, 1 – 8 turn on. INSTALLATION Power consumption •AC: Approx. 11 VA •DC: Approx. 8 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 500 g (1.1 lb) PERFORMANCE in percentage of span Setpoint accuracy (trip point accuracy): ±(0.1 % of FS + 1 digit) Display accuracy: ±(0.1 % of FS + 1 digit) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of max. span Response time: ≤ 1.5 sec. (0 – 100 % at 90 % setpoint) Excitation: Set value ±250 mV Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |