| 数据搜索系统,热门电子元器件搜索 |
|
AS4T-2-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
AS4T-2-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: AS4T AS4T SPECIFICATIONS ES-1608 Rev.16 Page 2/4 https://www.m-system.co.jp/ PV indication: Temperature in engineering unit Overrange indication: LEDs blinking Power saving mode: Displays turn off if the keys are untouched for a preset time period LEDs: Red LEDs turn on when coils are energized. (L1 and L2 for 2-point alarm. L1, L2, L3 and L4 for 4-point alarm.) INPUT SPECIFICATIONS Input resistance: 1 MΩ min. Burnout sensing: 45 nA ±10 % Default setting: K (CA) -100.0 – +999.9°C Minimum step: -199.9 to 999.9: 0.1 Not greater than -200, not lower than 1000: 1 Temperature range T/C USABLE RANGE CONFORMANCE LIMIT °C °F °C °F (PR) * K (CA) * E (CRC) * -52 to +1860 -272 to +1472 -272 to +1020 -61.6 to +3380 -458 to +2682 -458 to +1868 150 -200 -200 302 -328 -328 J (IC) T (CC) * B (RH) * -260 to +1300 -272 to +500 24 to 1920 -436 to +2372 -458 to +932 75.2 to 3488 -260 -200 450 -436 -328 842 R * S * C (WRe 5-26) -100 to +1860 -100 to +1860 -52 to +2416 -148 to +3380 -148 to +3380 -61.6 to +4381 150 150 -52 302 302 -61.6 N U L P (Platinel II) -272 to +1400 -252 to +600 -252 to +1000 -52 to +1496 -458 to +2552 -422 to +1112 -422 to +1832 -61.6 to +2725 -200 -252 -252 -52 -328 -422 -422 -61.6 * For temperatures ranges near the lower limit of the usable range, the transmitter may not satisfy the described accuracy. OUTPUT SPECIFICATIONS ■ Quad Alarm Relay rating: 120 V AC @ 1 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage(Note): 380 V AC or 125 V DC Maximum switching power(Note): 120 VA or 30 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles ■ Dual Alarm Relay rating: 120 V AC @ 5 A (cos ø = 1) 240 V AC @ 2.5 A (cos ø = 1) 30 V DC @ 5 A (resistive load) Maximum switching voltage(Note): 380 V AC or 125 V DC Maximum switching power(Note): 600 VA or 150 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles (Note): The value indicate capacity of output relay in equipment. Use within relay rating for EU and UL. 0 50 100 ▲ Input (%) LL L ▲ ▲ HH H L2 (1–2) ON ▲ L3 (1–3) ON L4 (9–11) ON OFF OFF L1 (9–10) ON OFF OFF Alarm Trip Operation Terminal No. in parentheses Example with quad N.O. contacts (LL, L, H, HH) Trip Operation in Power Failure • Output code 2: All relays turn off. • Output code 3: All relays turn on. • Output code 5: Terminals 1 – 3, 9 – 11 turn on. INSTALLATION Power consumption •AC: ≤ 6 VA •DC: ≤ 3.5 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 500 g (1.1 lb) PERFORMANCE in percentage of FS input Setpoint accuracy (trip point accuracy): ±(0.1 % of FS + 1 digit) Display accuracy: ±(0.1 % of FS + 1 digit) Cold junction compensation error: ±0.5°C or ±0.9°F (at 20°C ±10°C or 68°F ±18°F) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 1.5 sec. (0 – 100 % at 90 % setpoint) Burnout response: ≤ 5 sec. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (output) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |