| 数据搜索系统,热门电子元器件搜索 |
|
AS4V-2-M2/UL 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
AS4V-2-M2/UL 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 3 page ![]() MODEL: AS4V AS4V SPECIFICATIONS ES-1609 Rev.20 Page 2/5 https://www.m-system.co.jp/ • Display range scaling • Power ON-delay time • Alarm ON-delay time • Moving average • Hi/Lo trip operation • Coil at alarm • Hysteresis (deadband) • 0 %, 100 % input setting • Latching control • Others (Refer to the instruction manual) ■ DISPLAY LED: 8 mm (.31”) 7 segment, red Number of display digits: 4 digits for DATA display; 2 digits for ITEM display Range: -1999 to 9999 (decimal point position selectable) PV indication: Input signal in engineering unit Overrange indication: LEDs blinking Power saving mode: Displays turn off if the keys are untouched for a preset time period LEDs: Red LEDs turn on when coils are energized. (L1 and L2 for 2-point alarm. L1, L2, L3 and L4 for 4-point alarm.) INPUT SPECIFICATIONS ■ DC Current: 0 – 50 mA DC; shunt resistor attached to input terminals (0.5 W) Operational range: 0 – 70 mA DC (with 100 Ω / 0.5 W) Minimum increment: 0.1 mA Default setting: 4 – 20 mA DC ■ DC Voltage: -1 – +1 V DC for S1; -10 – +10 V DC for S2 Operational range: -1.15 – +1.15 V DC for S1; -11.5 – +11.5 V DC for S2 Minimum increment: 10 mV for S1; 100 mV for S2 Default setting: -1 – +1 V DC for S1; -10 – +10 V DC for S2 OUTPUT SPECIFICATIONS ■ Quad Alarm Relay rating: 120 V AC @ 1 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage(Note): 380 V AC or 125 V DC Maximum switching power(Note): 120 VA or 30 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles ■ Dual Alarm Relay rating: 120 V AC @ 5 A (cos ø = 1) 240 V AC @ 2.5 A (cos ø = 1) 30 V DC @ 5 A (resistive load) Maximum switching voltage(Note): 380 V AC or 125 V DC Maximum switching power(Note): 600 VA or 150 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles ■ Small load current type Relay rating: 30 V DC @ 1 A (resistive load) Maximum switching voltage(Note): 220 V DC Maximum switching power(Note): 30 W (resistive load) Minimum load: 1 V DC @ 1 mA Mechanical life: 5 × 107 cycles (Note): The value indicate capacity of output relay in equipment. Use within relay rating for EU and UL. 0 50 100 ▲ Input (%) LL L ▲ ▲ HH H L2 (1–2) ON ▲ L3 (1–3) ON L4 (9–11) ON OFF OFF L1 (9–10) ON OFF OFF Alarm Trip Operation Terminal No. in parentheses Example with quad N.O. contacts (LL, L, H, HH) Trip Operation in Power Failure • Output code 2, 2A: All relays turn off. • Output code 3, 3A: All relays turn on. • Output code 5, 5A: Terminals 1 – 3, 9 – 11 turn on. INSTALLATION Power consumption •AC: ≤ 6 VA •DC: ≤ 3.5 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 500 g (1.1 lb) PERFORMANCE in percentage of FS input Setpoint accuracy (trip point accuracy): ±(0.1 % of FS + 1 digit) Display accuracy: ±(0.1 % of FS + 1 digit) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |