| 数据搜索系统,热门电子元器件搜索 |
|
CTH 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
CTH 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: CTH CTH SPECIFICATIONS ES-1909 Rev.9 Page 2/4 https://www.m-system.co.jp/ Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) Input filter: Selectable with the front switch INPUT SPECIFICATIONS Frequency: 4 Hz – 200 kHz (-3 dB) or 4 Hz – 2 kHz (-3 dB) Input burden: 0.5 VA max. Overload capacity: 1000 % of rating for 3 sec., 200 % for 10 sec., 120 % continuous Operational range: 0 – 120 % of rating 10 4 100 1k 2k 10k 100k 200k (Hz) –10 0 (dB) –3 Frequency Characteristics OUTPUT SPECIFICATIONS ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. ■ DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max.; 5 mA for negative voltage output; at ≥ 0.5 V INSTALLATION Power input • AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz, approx. 2 VA • DC: Operational voltage range: rating ±10 %, or 85 – 150 V for 110 V rating (ripple 10 % p-p max.) approx. 2 W (80 mA at 24 V) Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 300 g (0.66 lb) PERFORMANCE in percentage of span Accuracy: ±0.3 % at 20 Hz – 1 kHz ±7 % at 7 Hz – 100 kHz Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) at 20 Hz – 1 kHz ±0.35 %/°C (±0.19 %/°F) at 7 Hz – 100 kHz Response time: Approx. 1.5 sec. (0 – 90 %) Ripple: 0.5 %p-p max.(The output ripple may increase when there is great difference between the frequencies of input signal and power supply) Line voltage effect: ±0.1 % over voltage range (input 5 - 100 %) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input to output to power: Reinforced insulation (300 V) RoHS Directive |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |