| 数据搜索系统,热门电子元器件搜索 |
|
KS2TR2-1-R 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
KS2TR2-1-R 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 4 page ![]() MODEL: KS2TR2 KS2TR2 SPECIFICATIONS ES-3606 Rev.6 Page 1/4 https://www.m-system.co.jp/ Plug-in Signal Conditioners K-UNIT TEMPERATURE INPUT LIMIT ALARM (digital adjustments; dual alarm trip) Functions & Features • Providing relay contact closures at preset DC input levels • Dual (Hi/Lo) trip • Front digital displays • Programmable with front keys Typical Applications • Various alarm applications 50 (1.97) 110 (4.33) 70 (2.76) mm (inch.) MODEL: KS2TR2–1–[1][2] ORDERING INFORMATION • Code number: KS2TR2-1-[1][2] Specify a code from below for each of [1] and [2]. (e.g. KS2TR2-1-R/Q) • Specify the specification for option code /Q (e.g. /SET) TEMPERATURE INPUT Thermocouple input K(CA), E(CRC), J(IC), T(CC), B(RH), R, S, P(Platinel Ⅱ), C(WRe 5-26), N RTD input JPt 100 (JIS ’89) , Pt 100 (JIS ’97, IEC) OUTPUT 1: Relay; SPDT or transfer contact [1] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS blank: none /Q: Options other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-3606) GENERAL SPECIFICATIONS Construction: Panel flush mounting, plug-in Connection: M3.5 screw terminals Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Isolation: Input to SET1 to SET2 to power Time constant for the input filter (P-dF): 5.0 to 900.0 sec. (0 – 63 %) Alarm relay switching delay time (P-d1, P-d2): 1 to 10 sec.; programmable independently for each setpoint Programming: Front key Setpoint adjustment (ST1, ST2): -5 to +105 %; programmable independently for each setpoint Deadband (hysteresis) (HYS1, HYS2): 0 – 102 %; programmable independently for each setpoint Burnout: Upscale or downscale or no burnout Cold junction compensation (CJM): ON or OFF; for thermocouple input only; CJC sensor incorporated Power ON delay (P-d0): 0 to 20 sec. Read rate: 0.5 sec. Temperature unit (P-F): °C, °F Alarm mode (P-A1, P-A2): Programmable independently for each setpoint; See Table below. Param. Code (P-A1) (P-A2) Alarm Modes Trip Operation Set Value Latching Hold* Relay & LED Behavior in Tripped Conditions 0 No alarm ---- ---- ---- 1 High Absolute value Without LED ON Coil energized 2 Low Absolute value Without LED ON Coil energized 3 High Absolute value With LED ON Coil energized 4 Low Absolute value With LED ON Coil energized 5 High Absolute value Without LED ON Coil de-energized 6 Low Absolute value Without LED ON Coil de-energized 7 High Absolute value With LED ON Coil de-energized 8 Low Absolute value With LED ON Coil de-energized *Without latching hold function, the unit is tripped upon starting operation when the unit is set to Low alarm. With the function, the unit is NOT tripped until the temperature goes once above and then below the setpoint. |
类似零件编号 - KS2TR2-1-R |
|
类似说明 - KS2TR2-1-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |