| 数据搜索系统,热门电子元器件搜索 |
|
M2PRU-A27P-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M2PRU-A27P-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 6 page ![]() MODEL: M2PRU M2PRU SPECIFICATIONS ES-5076 Rev.18 Page 2/6 http://www.m-system.co.jp/ CAUTION 1) The M2PRU’s output waveform is not uniform due to its scaling method. The user must be aware that it may be inconvenient for certain types of application. 2) The M2PRU is designed to accept at the maximum of 100 kHz, which may cause errors due to chattering in the input pulses. A filter circuitry (time constant: approx. 1 msec.) is incorporated to eliminate unwanted chattering when the mechanical contact input is specified. It is effective for most relay types, however, an external CR filter as indicated below, could be added if the user need improvement. Limit the input frequency to 10 Hz at maximum. C + ‒ Relay R PULSE SCALER C = 100 µF R = 100Ω GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Chattering protection: Filter provided for mechanical contact input (time constant: approx. 1 msec.) Input pulse sensing: DC coupled; capacitor coupling (automatic trigger*) is field selectable with the side DIP switch for the voltage pulse input. *Capacitor coupling, with which the detecting levels are automatically set within two peaks of the waveforms, is effective way to detect those with DC offset. However, it may be ineffective if the duty ratio is extremely high or low. The automatic trigger method can compensate such irregular pulses. Scaling factor adjustment: 10-position rotary switch; 1.0000 × 100 – 0.0001 × 10–6; factory set to 1.0000 × 100 if not specified when ordering Output pulse width adjustment: Single-turn screwdriver adjustment (front); 5 μsec. – 400 msec. (one-shot type); Factory set to 5 μsec. except for the mechanical contact input set to 15 msec. or AC/DC switch output set to 500 μsec. (Min. 400 μsec. recommended for AC/DC switch output of which the internal voltage drop value may increase with a shorter pulse width.) Output pulse width range selector: Double-throw SW (front) INPUT SPECIFICATIONS Excitation: Shortcircuit protection; limited to approx. 40 mA at shortcircuit ■ Open Collector Frequency range: 0 – 100 kHz Pulse width time requirement: Min. 5 μsec. for ON and OFF Sensing: Approx. 24 V DC @2 mA Detecting levels: ≤ 400 Ω / 0.8 V for ON, ≥ 1200 Ω / 2.4 V for OFF ■ Mechanical Contact Frequency range: 0 – 30 Hz Pulse width time requirement: Min. 10 msec. for ON and OFF Sensing: Approx. 24 V DC @2 mA Detecting levels: ≤ 400 Ω / 0.8 V for ON, ≥ 1200 Ω / 2.4 V for OFF ■ Voltage Pulse Waveform: Square or sine Frequency range: 0 – 100 kHz (min. 10 Hz for sine waves) Pulse width time requirement: ≥ 5 μsec. for high and low levels Input impedance: ≥ 10 kΩ Max. input voltage across the terminals: ±50 V Detecting levels DC coupled: ≥ 2 V DC for high level; ≤ 1 V DC for low level Capacitor coupled: ≥ 2 Vp-p ■ Two-wire Current Pulse Frequency range: 0 – 100 kHz Pulse width time requirement: Min. 5 μsec. for high and low levels Detecting levels: ≥ 10 mA for high level ≤ 5 mA for low level Maximum current: ±30 mA Input resistance: Receiving resistor 200 Ω |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |