| 数据搜索系统,热门电子元器件搜索 |
|
M2XPA3-A24V2-R 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M2XPA3-A24V2-R 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 6 page ![]() MODEL: M2XPA3 M2XPA3 SPECIFICATIONS ES-5104 Rev.14 Page 3/6 http://www.m-system.co.jp/ INPUT SPECIFICATIONS Excitation: Shortcircuit protection; 30 mA max. at shortcircuit Frequency ranges: 0 – 10 mHz, 0 – 100 mHz, 0 – 1 Hz, 0 – 10 Hz, 0 – 100 Hz, 0 – 1 kHz, 0 – 10 kHz, 0 – 200 kHz (up to 10 Hz for mechanical contact) If not specified, Input frequency factory default will be 0 – 100 kHz. (0 – 10 Hz for mechanical contact) Minimum pulse width time requirement: 2.5 μsec. for both ON and OFF. (50 msec. for mechanical contact) Minimum span: 10 % of the selected frequency range (5 % of the selected frequency range when the range is 0 – 200 kHz.) Noise filter: See Table 2 Choose the noise filter type appropriate for the selected frequency range to ensure the described accuracy. ■ Open Collector & Mechanical Contact Input requirements EXC SENSING OFF ON 4V Approx. 3V/0.7mA ≥2kΩ/1V ≤200Ω/0.2V 8V Approx. 6V/1.5mA ≥4kΩ/3V ≤600Ω/1V 12V Approx. 9V/2.3mA ≥2kΩ/3V ≤400Ω/1V Detecting level (detecting voltage in the internal circuit) factory default: 0.6 V (4 V excitation) 2 V (8 V / 12 V excitation) ■ Voltage Pulse Waveform: Square or sine Input impedance: ≥ 10 kΩ Input amplitude: Min. 0.1 Vp-p, max. 100 Vp-p Max. voltage between input terminals: See table 1. Detecting level (detecting voltage in the internal circuit): -2 – +4 V ■ Two-wire Current Pulse Input resistance: Receiving resistor 100 Ω Input range: 0 – 25 mA Input amplitude: Min. 10 mAp-p, max. 25 mAp-p Detecting level (detecting voltage in the internal circuit): -2 – +4 V ■ RS-422 Line Driver Pulse Receiver: Conforms to RS-422 ■ VOLTAGE PULSE 100V max. Amplitude Vinp-p t Volts DC Offset [Table 1] 50 – 100 Vp-p 25 – 50 Vp-p 10 – 25 Vp-p 5 – 10 Vp-p 1 – 5 Vp-p 0.5 – 1 Vp-p 0.1 – 0.5 Vp-p** Open collector Mechanical contact 2-wire current pulse 100 V* 50 V 25 V 10 V 5 V 1 V 0.5 V ---- 1/20 1/10 1/5 1/2 1 5 10 1 PULSE AMPLITUDE MAX. VOLTAGE AT INPUT TERMINALS SENSITIVITY SCALE *Limited to ≤70V for CE conformance or UL approval. **Input frequency ≤50 kHz A specific sensitivity scale is applied according to the pulse amplitude by setting up the DIP switch and PC Configurator Software (model: JXCON). The scaled input voltage is then compared to the detecting level at -2.00 through +4.00V. With DC coupling, the scaled maximum input voltage level voltage must be higher than and the scaled minimum input voltage level must be lower than the detecting level so that the pulse state is accurately detected. [Table 2] 0 – 10 mHz 0 – 100 mHz 0 – 1 Hz 0 – 10 Hz 0 – 100 Hz 0 – 1 kHz 0 – 10 kHz 0 – 200 kHz High High Low Low Low Low None None FREQUENCY RANGE NOISE FILTER Choose the noise filter type appropriate for the selected frequency range to ensure the described accuracy. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |