3 / 6 page ![]() MODEL: M3LU M3LU SPECIFICATIONS ES-2652 Rev.20 Page 3/6 http://www.m-system.co.jp/ PERFORMANCE Accuracy: See Table 1. Cold junction compensation error: ±0.5°C maximum at 10 – 40°C ±1.0°C maximum at 0 – 50°C ±0.9°F maximum at 50 – 104°F ±1.8°F maximum at 32 – 122°F Temp. coefficient: ±0.015 %/°C [±0.008 %/°F] at -5 to +55°C [23 to 131°F] of max. range ±0.03 %/°C [±0.016 %/°F] for the following conditions: • DC, T/C input spans ≤ 10 mV • RTD, potentiometer, resistance spans ≤ 80 Ω • in an ambient exceeding 55°C [131°F] or below -5°C [23°F] Response time: ≤ 0.2 sec. (0 – 90 %, DC input) With the Option A, the Sync Filter set to the fastest frequency on the PC Configurator Software. Default is set to have 0.5 sec. response. Burnout response: ≤ 10 sec. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength AC powered: 2000 V AC @ 1 minute (input to output to power to ground) DC powered: 1500 V AC @ 1 minute (input to output or power to ground) 500 V AC @ 1 minute (output to power) CALCULATION EXAMPLES OF OVERALL ACCURACY ■ CALCULATION EXAMPLES OF OVERALL ACCURACY IN % • DC Voltage 1) 0 – 200 mV Absolute value accuracy (Table 1): 40μV 40μV ÷ 200000μV × 100 = 0.02 % < 0.1 % ➠ Overall accuracy = ±0.1 % of span 2) 0 – 4 mV Absolute value accuracy (Table 1): 10μV 10μV ÷ 4000μV × 100 = 0.25 % > 0.1 % ➠ Overall accuracy = ±0.25 % of span • Thermocouple 1) K thermocouple, 0 – 1000°C Absolute value accuracy (Table 1): 0.25°C CJC error (0.5°C) added: 0.75°C 0.75°C ÷ 1000°C × 100 = 0.075 % < 0.1 % ➠ Overall accuracy including CJC error = ±0.1 % of span 2) K thermocouple, 50 – 150°C Absolute value accuracy (Table 1): 0.25°C CJC error (0.5°C) added: 0.75°C 0.75°C ÷ (150 – 50)°C × 100 = 0.75 % > 0.1 % ➠ Overall accuracy including CJC error = ±0.75 % of span • RTD 1) Pt 100, -200 – 800°C Absolute value accuracy (Table 1): 0.15°C 0.15°C ÷ (800 – -200)°C × 100 = 0.015 % < 0.1 % ➠ Overall accuracy = ±0.1 % of span 2) Pt 100, 0 – 100°C Absolute value accuracy (Table 1): 0.15°C 0.15°C ÷ 100°C × 100 = 0.15 % > 0.1 % ➠ Overall accuracy = ±0.15 % of span STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 Approval: UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.1010-1) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |