| 数据搜索系统,热门电子元器件搜索 |
|
M3LU2-M2/A/Q 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M3LU2-M2/A/Q 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 6 page ![]() MODEL: M3LU2 M3LU2 SPECIFICATIONS ES-2653 Rev.8 Page 3/6 http://www.m-system.co.jp/ INSTALLATION Power Consumption •AC: Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 264 V •DC: Approx. 3 W Operating temperature: -25 to +60°C (-13 to +140°F) Operating humidity: 30 to 95 %RH (non-condensing) Mounting: DIN rail Weight: 100 g (3.53 oz) PERFORMANCE Accuracy: See Table 1. Cold junction compensation error: ±1.0°C at 0 – 50°C (±1.8°F at 32 – 122°F) Temp. coefficient: ±0.015 %/°C [±0.008 %/°F] at -5 to +55°C [23 to 131°F] of max. range ±0.03 %/°C [±0.016 %/°F] for the following conditions: • DC, T/C input spans ≤ 10 mV • RTD, potentiometer, resistance spans ≤ 80 Ω • in an ambient exceeding 55°C [131°F] or below -5°C [23°F] Response time: ≤ 0.2 sec. (0 – 90%, DC input) (With the Option A, the Sync Filter set to the fastest frequency on the PC Configurator Software. Default is set to have 0.5-second response.) Burnout response: ≤ 10 sec. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) CALCULATION EXAMPLES OF OVERALL ACCURACY • DC Voltage 1) 0 – 200 mV Absolute value accuracy (Table 1): 40 μV 40 μV ÷ 200000 μV × 100 = 0.02 % < 0.1 % ➠ Overall accuracy = ±0.1% of span 2) 0 – 4 mV Absolute value accuracy (Table 1): 10 μV 10 μV ÷ 4000 μV × 100 = 0.25 % > 0.1% ➠ Overall accuracy = ±0.25 % of span • Thermocouple 1) K thermocouple, -150 – +1370°C Absolute value accuracy (Table 1): 0.25°C CJC error (1.0°C) added: 1.25°C 1.25°C ÷ 1520°C × 100 = 0.082 % < 0.1 % ➠ Overall accuracy including CJC error = ±0.1 % of span 2) K thermocouple, 50 – 150°C Absolute value accuracy (Table 1): 0.25°C CJC error (1.0°C) added: 1.25°C 1.25°C ÷ (150 – 50)°C × 100 = 1.25 % > 0.1 % ➠ Overall accuracy including CJC error = ±1.25 % of span • RTD 1) Pt 100, -200 – 800°C Absolute value accuracy (Table 1): 0.15°C 0.15°C ÷ (800 – -200)°C × 100 = 0.015 % < 0.1 % ➠ Overall accuracy = ±0.1 % of span 2) Pt 100, 0 – 100°C Absolute value accuracy (Table 1): 0.15°C 0.15°C ÷ 100°C × 100 = 0.15 % > 0.1 % ➠ Overall accuracy = ±0.15 % of span STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |