3 / 4 page ![]() MODEL: M2REB M2REB SPECIFICATIONS ES-5097 Rev.11 Page 3/4 http://www.m-system.co.jp/ STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.61010-1) FRONT VIEW (C) Ratio/Bias Selector The front cover cannot be turned open by 180 deg. when there is no extra space between units. (A) Polarity Indicator LED (B) Ratio/Bias Display (E) Zero Adj. (F) Span Adj. (D) UP/DOWN Control Top: Ratio Bottom: Bias • How to Set the Ratio Turn the Ratio/Bias Selector (C) to the top. The Ratio/Bias Display (B) shows the current ratio (0.10 – 4.00). Press UP/DOWN Control (D) until the display shows a desired set value. The Polarity Indicator LED (A) is red when the set value is in positive range, green when in negative range. • How to Set the Bias Turn the Ratio/Bias Selector (C) to the bottom. The Ratio/Bias Display (B) shows the current bias (0 – 100%). Press UP/DOWN Control (D) until the display shows a desired set value. The Polarity Indicator LED (A) is red when the set value is in positive range, green when in negative range. • Fine Calibration Equation: Xo = KXi + B (proportional) Xo = KXi + B + 100 % (inverted) 1) Calculate the input signal Xi which results in 0 % output. Apply the calculated input and adjust with Zero Adj. (E) the output Xo to 0 %. 2) Calculate the input signal Xi which results in 100 % output. Apply the calculated input and adjust with Span Adj. (E) the output Xo to 100 %. 3) Apply the calculated zero point input again and check the output Xo. 4) If the output has been shifted, go through (1) through (3) again. The unit is factory set and calibrated to the following ratio and bias values. Proportional characteristics: ratio ( K) = 1, Bias (B) = 0% Inverted characteristics: ratio ( K) = -1, Bias (B) = 0% |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |