| 数据搜索系统,热门电子元器件搜索 |
|
M6NXAR-3-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M6NXAR-3-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: M6NXAR M6NXAR SPECIFICATIONS ES-7923 Rev.4 Page 2/4 http://www.m-system.co.jp/ tripped. Programming: Downloaded from PC Input type and range Input fine adjustments User’s RTD table (max. 300 points) Burnout (Upscale, downscale or no burnout) Alarm setpoint (input %) Trip action (High or Low) Relay coil (energized or de-energized) Power ON delay time (0 to 999 sec.) Alarm ON delay time (0 to 999 sec.) Hysteresis (deadband) (input %) Alarm test, and others Configurator connection: 2.5 dia. miniature jack; RS-232-C level Factory default setting Alarm setpoint: 80% Trip action: High Relay coil at alarm: Energized Power ON delay time: 5 seconds Alarm ON delay time: 0 seconds Hysteresis (deadband): 1.0% Burnout: Upscale ■Recommended solderless terminal (unit: mm (inch)) 3.2 (.13) dia. 4 min. (.16) 5.5 max. (.22) INPUT SPECIFICATIONS Input: 2- or 3-wire RTD Maximum leadwire resistance: 10 Ω per wire Sensing current: ≤ 1.5 mA (≤ 0.15 mA for Pt 1000) Minimum span: 20°C or 36°F Resistance range: 0 - 500 Ω (Input code: 1, 3, 4, 5, 9) 0 - 5 kΩ (Input code: 7) If not specified, the input range is 0 - 100°C. OUTPUT SPECIFICATIONS ■ Relay Output Relay rating: 250 V AC @2 A (cos ø = 1) 30 V DC @2 A (resistive load) Maximum switching voltage: 250 V AC or 125 V DC Maximum switching power: 500 VA or 60 W Minimum load: 5 V DC @100 mA Mechanical life: 5 × 106 cycles (rate 180/min.) 0 50 100 Input (%) ▲ Setpoint Output (3–4)ON (3–2)ON • Setting Example Hi alarm (coil energized at alarm) or Lo alarm (coil de-energized at alarm) Alarm Trip Operation Terminal No. in parentheses Trip operation in power failure: Terminals 3 – 4 turn ON. INSTALLATION Power consumption: Approx. 0.5 W Operating temperature: -20 to +55°C (-4 to +131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Installation Base (model: M6NBS) or DIN rail Weight: 65 g (2.3 oz) PERFORMANCE in percentage of span Setpoint accuracy (trip point accuracy) Pt and JPt: Whichever greater ±0.1 % of input range or ±0.15°C Cu10: ±1°C Temp. coefficient: ±0.01 %/°C (±0.006 %/°F) of max. span Response time: ≤ 1 sec. (0 – 100 % at 90 % setpoint) Burnout response time: ≤ 1 sec. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) CALCULATION EXAMPLES OF SETPOINT ACCURACY [Example] Input type Pt 100, Input range 0 – 100°C Setpoint accuracy *1 (0.15°C *2) ÷ Span (100°C) × 100 % *1. Calculate the accuracy in °C *2. 100 °C × 0.1 % = 0.1 °C ≤ 0.15 °C. 0.15 °C is used as input accuracy value. STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (output) Pollution Degree 2 Input or power to output: Reinforced insulation (300 V) RoHS Directive EN 50581 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |