| 数据搜索系统,热门电子元器件搜索 |
|
W2XR-7V3V2-R2/Q 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
W2XR-7V3V2-R2/Q 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 4 page ![]() MODEL: W2XR W2XR SPECIFICATIONS ES-5503 Rev.7 Page 1/4 http://www.m-system.co.jp/ Space-saving Dual Output Signal Conditioners Mini-MW Series RTD TRANSMITTER (PC programmable) Functions & Features • Accepts direct input from a RTD • 4-wire connection available • Two independent output ranges • Linearization and burnout • PC programmable • High-density mounting Typical Applications • Long distance transmission between the RTD and the transmitter • Combination with intrinsic safety barriers 88.5 (3.48) 29.5 (1.16) 124 (4.88) mm (inch) MODEL: W2XR–[1][2][3]-[4][5] ORDERING INFORMATION • Code number: W2XR-[1][2][3]-[4][5] Specify a code from below for each [1] through [5]. (e.g. W2XR-4Z1V3-M2/N/Q) • Temperature range (e.g. 0 – 100°C) • Output 1 range (e.g. 4 – 20 mA DC) • Output 2 range (e.g. 1 – 5 V DC) • Specify the specification for option code /Q (e.g. /C01/S01/SET) Note: If one of the outputs should be a current range, specify it for the Output 1 to allow a greater load. [1] INPUT RTD 1: JPt 100 (JIS'89) (Usable range: -200 to +500°C, -328 to +932°F; min.span: 20°C, 36°F) 3: Pt 100 (JIS'89) (Usable range: -200 to +650°C, -328 to +1202°F; min.span: 20°C, 36°F) 4: Pt 100 (JIS'97, IEC) (Usable range: -200 to +850°C, -328 to +1562°F; min.span: 20°C, 36°F) 5: Pt 50 Ω (JIS'81) (Usable range: -200 to +649°C, -328 to +1200°F; min.span: 20°C, 36°F) 7: Pt 1000 (Usable range: -200 to +850°C, -328 to +1562°F; min.span: 20°C, 36°F) 9: Cu 10 @25°C (Usable range: -50 to +250°C, -58 to +482°F; min.span: 20°C, 36°F) 0: Specify (Please provide a resistance table.) (Configurator software is used to change the input type and precise range.) [2] OUTPUT 1 Current Z1: Range 0 – 20 mA DC Voltage V2: Range -10 – +10 V DC V3: Range -5 – +5 V DC (Configurator software is used to change output over the described range of the selected suffix code. For changing between suffix codes, set the Output Range Selector on the side of unit before software adjustment.) [3] OUTPUT 2 Same range availability as Output 1 Y: None (Configurator software is used to change output over the described range of the selected suffix code. For changing between suffix codes, set the Output Range Selector on the side of unit before software adjustment.) [4] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) [5] OPTIONS (multiple selections) Standards & Approvals (must be specified) /N: Without CE Other Options blank: none /Q: Option other than the above (specify the specification) |
类似零件编号 - W2XR-7V3V2-R2/Q |
|
类似说明 - W2XR-7V3V2-R2/Q |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |