| 数据搜索系统,热门电子元器件搜索 |
|
M2BD-041-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M2BD-041-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 7 page ![]() MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 2/7 http://www.m-system.co.jp/ Isolation: Transformer D/A conversion output: 16-bit binary Signal range 0 – 100 % is converted into hexadecimal 0000 – 1770 (0 – 6000). -15 to 0 % is represented by 2’s complements. Overall range is represented by hexadecimal FC7C – 1AF4 (- 900 – +6900), for -15 – +115 %. Note: In the firmware version 3.00 or later, analog output range 0 – 100% can be converted into hexadecimal 0000 – 2710 (0 – 10000). In addition, negative values of analog output range -15 to 0% can be converted into signed absolute values. Refer to the instruction manual for details. INSTALLATION Power Consumption: •AC: approx. 6 VA without I/O module approx. 30 VA with 4 modules (M2DY) approx. 50 VA with 8 modules (M2DY) approx. 90 VA with 16 modules (M2DY) Current consumption: •DC approx. 0.25 A without I/O module approx. 1 A with 4 modules (M2DY) approx. 1.5 A with 8 modules (M2DY) approx. 2.5 A with 16 modules (M2DY) Supply voltage to network: 11 – 25 V DC supplied through the network terminal block Supply current to network: 60 mA max. @ 24 V Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface Weight: Without I/O module M2BD-04 1.2 kg (2.6 lb) M2BD-08 1.5 kg (3.3 lb) M2BD-16 2 kg (4.4 lb) PERFORMANCE in percentage of span A/D conversion: Accuracy of input module ±0.1% D/A conversion: Accuracy of M2VS ±0.1 % Permissible power failure duration: ≤ 10 msec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1000 V AC @1 minute (power to I/O module to DeviceNet module to FG1) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (input) Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 3111-1, CAN/CSA-C22.2 No.1010-1) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |