| 数据搜索系统,热门电子元器件搜索 |
|
WJPAD2-732-R 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
WJPAD2-732-R 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 5 page ![]() MODEL: WJPAD2 WJPAD2 SPECIFICATIONS ES-2275 Rev.2 Page 3/5 http://www.m-system.co.jp/ 24 V: Approx. 16 V / 4.7 mA: ≥ 200 kΩ: ≤ 200 Ω Detecting level: 2 V (Detecting voltage in the internal circuit.) Detecting pulse edge: OFF (input monitor LED ON) to ON (input monitor LED OFF) ■ Voltage Pulse Waveform: Square or sine Input impedance: 10 kΩ min. Pulse amplitude: 0.1 – 100 Vp-p Max. voltage between input terminals: 50 V Detecting level: 0 – 5 V (Detecting voltage in the internal circuit.) Detecting pulse state: A pulse rise detected when the input voltage goes above the detecting level; a pulse sink detected when it goes below the level. ■ Two-wire Current Pulse Input resistance: Receiving resistor 100 Ω Input range: 0 – 25 mA Minimum pulse amplitude: 10 mA Detecting level: 0 – 5 V (Detecting voltage in the internal circuit.) Detecting pulse state: The input resistor (100 Ω) converts the current signal into 0 – 2.5 V. A pulse rise detected when the voltage goes above the detecting level; a pulse sink detected when it goes below the level. 50V max. Amplitude Vinp-p t Volts DC Offset ■ Voltage pulse waveform OUTPUT SPECIFICATIONS ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 12 V max. for Output 1; 7 V max. for Output 2 ■ DC Voltage: -10 – +10 V DC Minimum span: 10 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max.; at ≥ 0.5 V ■ Alarm Output: Relay contact Rated load: 30V DC @ 1 A (resistive load) Maximum switching voltage: 110 V DC Maximum switching power:30 W Minimum load: 10 mV DC @ 0.1 mA Mechanical life: 5 × 107 cycles (180 cycles/minute) For maximum relay life with inductive loads, external protection is recommended. INSTALLATION Power input •AC: Operational voltage range 85 – 132 V, 47 – 66 Hz, approx. 6.6 VA •DC: Operational voltage range: Rating ±10 %, or 85 – 150 V for 110 V rating; ripple 10 %p-p max.; Approx. 3.9 W (145 mA at 24 V) Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 300 g (0.66 lb) PERFORMANCE in percentage of span Accuracy: Input accuracy + output accuracy Input accuracy: ±0.05% of the selected freq. range Inversely proportional to the input span. [Example] Open collector input, 0 – 50 kHz Selected Freq. Range 100 kHz ÷ Input Span 50 kHz × Accuracy 0.05 % + Output Accuracy 0.05 % = ±0.15 % Output accuracy: ±0.05 % of the output range Alarm setpoint accuracy: ±0.1 % (or ±0.2 % at ≥ 10 kHz) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: 0.5 sec. + 1 pulse cycle (0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input or alarm output to output 1 or output 2 to power to ground) 1000 V AC @ 1 minute (output 1 to output 2) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |