| 数据搜索系统,热门电子元器件搜索 |
|
ZC01 数据表(PDF) 4 Page - Zhengzhou Winsen Electronics Technology Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
ZC01 数据表(HTML) 4 Page - Zhengzhou Winsen Electronics Technology Co., Ltd. |
|
4 / 5 page ![]() Zhengzhou Winsen Electronics Technology Co., Ltd www.winsen-sensor.com Tel: 86-371-67169097/67169670 Fax: 86-371-60932988 Email: sales@winsensor.com Leading gas sensing solutions supplier in China! 2. Usage Steps 2.1 Insert the module into the socket, cover the shell and twist the screw tightly, connect to DC power supply, turn on the switch to light up the miner’s lamp. 2.2 When the CH4 concentration gets higher than the preset alarm point, the module can control the lamp to flicker with alarming; when the CH4 concentration is lower than the preset alarm point, the module can control the lamp to recovery the normal light status. 3.Calibration 3.1 Zero calibration Turn on and keep the status for 10 minutes, press the “-” key in the remote control direct to the indicator, then the zero calibration is finished. 3.2 Set the alarm point After warming up and zero calibration, flow 1.0%CH4(flow should between 150-160mL/min) into the gas inlet, press “+”key in the remote control at the same time, then the yellow light begins flicking and it keeps about for 20 seconds. The calibration finishes once the flicking stops. Then the red light is flicking and main light begins twinkle, the alarm point is set. 3.3 Check the alarm point After warming up, flow in 0.90%CH4 gas with 150-160mL/min flow. After the flowing is stability for 20s, the module shouldn’t alarm and the light doesn’t flicking. If it flicks, it means the preset alarm point is lower and calibration should be done again; Then flow in 1.0%CH4 gas with 50-160mL/min flow, after the flowing is stability for 20s, the module should alarm. Otherwise calibration should be done again until it confirm to the above description. 4 Maintain 4.1 Keep the louver clean and make the gas composition in module and out module same. 4.2 Please do the calibration using recommended gas of coal industry weekly to ensure the good accuracy of the alarm point. 4.3 Please brush the module surface gently to remove pollutants if required. Do not use acidic or alkaline cleaning agent. 4.4 If the module is sprinkled with water accidently, please cut the power immediately, and send the |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |