1 / 3 page ![]() MODEL: 17RP http://www.m-system.co.jp/ 17RP SPECIFICATIONS ES-2967 Rev.0 Page 1/3 Rack-mounted Power Transducers 17-RACK VAR TRANSDUCER Functions & Features • Providing a DC output signal in proportion to AC reactive power • DC output containing little ripple is ideal for computer input • "Time division multiplication" method accepts distorted waveforms Typical Applications • Centralized monitoring and control of power management system in a manufacturing facility or building MODEL: 17RP–1[1][2]6–R ORDERING INFORMATION • Code number: 17RP-1[1][2]6-R Specify a code from below for each [1] and [2]. (e.g. 17RP-11P6-R) • Var range (e.g. LAG 1000 – LEAD 1000 var) CONFIGURATION 1: 3-phase / 3-wire [1] INPUT (unbalanced load) (Voltage must be balanced.) 1: 110 V / 5 A AC 2: 110 V / 1 A AC 3: 220 V / 1 A AC 4: 220 V / 5 A AC [2] OUTPUT SIGNAL POLARITY P: Negative in lag, positive in lead M: Negative in lead, positive in lag OUTPUT Voltage 6: 1 – 5 V DC (Load resistance 5000 Ω min.) AUXILIARY POWER SUPPLY DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) GENERAL SPECIFICATIONS Construction: Rack-mounted; terminal access via screw terminals on the front and connector on the rear; terminal cover provided Connection Input: M3.5 screw terminals (torque 0.8 N·m) Output: Connector Auxiliary power: Supplied from connector Screw terminal: Nickel-plated steel Isolation: Voltage input to current input to output to auxiliary power Computation: Time division multiplication Overrange output: Approx. -10 to +120 % Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) INPUT SPECIFICATIONS Frequency: 50 or 60 Hz • Voltage Input Operational range: 0 – 120 % of rating Overload capacity: 150 % of rating for 10 sec., 120 % continuous • Current Input Operational range: 0 – 120 % of rating Overload capacity: 1000 % of rating for 3 sec., 200 % for 10 sec., 120% continuous ■ How To Determine Var Range Calibration Range [var] = (Measuring Range) ÷ ((VT Ratio) × (CT Ratio)) Check that the required calibration range is within the available range in the table. [example] 3-phase / 3-wire, measuring range 75 kvar, VT 220 / 110 V, CT 250 / 5 A (75 × 103 [var])÷((220 / 110) × (250 / 5))= 750 [var] I INPUT RANGE • 3-phase / 3-wire INPUT BURDEN (VA) STD.RANGE AVAILABLE RANGE VOLT. CURR. 110V/1A 110V/5A 220V/1A 220V/5A 200 var 1000 var 400 var 2000 var 0.2 /phase 0.4 /phase 0.1/ph 0.5/ph 0.1/ph 0.5/ph 100 – 240 var 500 – 1200 var 200 – 480 var 1000 – 2400 var |
类似零件编号 - 17RP-12P6-R |
|
类似说明 - 17RP-12P6-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |