1 / 2 page ![]() MODEL: 18CE 18CE SPECIFICATIONS ES-1837 Rev.7 Page 1/2 http://www.m-system.co.jp/ Rack-mounted DCS Signal Conditioners 18-RACK CT CONVERTER Functions & Features • Converting an alternating current from a current transformer into two standard process signals • Minimum ripple • True RMS sensing • Second channel output available at the front terminals and at the Standard Rack connector Typical Applications • Centralized monitoring and control of motors, pumps or heaters by DCS • Monitoring power line and power supply current MODEL: 18CE–[1]66–R ORDERING INFORMATION • Code number: 18CE-[1]66-R Specify a code from below for [1]. (e.g. 18CE-166-R) [1] INPUT Current 1: 0 – 1 A AC 5: 0 – 5 A AC OUTPUT 1 Voltage 6: 1 – 5 V DC (Load resistance 2000 Ω min.) OUTPUT 2 Voltage 6: 1 – 5 V DC (Load resistance 2000 Ω min.) POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) GENERAL SPECIFICATIONS Construction: Rack-mounted; terminal access via screw terminals on the front and connector on the rear; terminal cover provided Connection Input: M3.5 screw terminals (torque 0.8 N·m) Output 1: Connector Output 2: M3.5 screw terminals (torque 0.8 N·m) and connector Power input: Supplied from connector Screw terminal: Nickel-plated steel Isolation: Input to output 1 to output 2 to power Input waveform: Up to 15 % of 3rd harmonic content Overrange output: Approx. 0 to 120 % at 1 – 5V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) INPUT SPECIFICATIONS Frequency: 50 or 60 Hz Input burden: 0.5 VA max. Overload capacity: 500 % of rating for 5 sec., 120 % continuous Operational range: 0 – 120 % of rating INSTALLATION Current consumption: Approx. 35 mA Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Standard Rack 18BXx or 18KBXx Weight: 150 g (0.33 lb) PERFORMANCE in percentage of span Accuracy: ±0.4 % Temp. coefficient: ±0.02 %/°C (±0.01 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) Ripple: 0.5 %p-p max. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (input to output 1 or output 2 or power) 500 V AC @ 1 minute (output 1 to output 2 to power) 1500 V AC @ 1 minute (input or output or power to ground) |
类似零件编号 - 18CE |
|
类似说明 - 18CE |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |