| 数据搜索系统,热门电子元器件搜索 |
|
18JDL-A366-R 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
18JDL-A366-R 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 3 page ![]() MODEL: 18JDL 18JDL SPECIFICATIONS ES-1874 Rev.13 Page 1/3 http://www.m-system.co.jp/ Rack-mounted DCS Signal Conditioners 18-RACK CURRENT LOOP SUPPLY (linearizing; field-programmable) Functions & Features • Powering a 4 – 20 mA DC current loop • Microprocessor based • Shortcircuit protection • Applicable to smart transmitters • Field-programmable linearization data • Loop testing via hand-held programmer PU-2x • Usable as Linearizer for 4 – 20 mA DC signals • Second channel output available at the front terminals and at the Standard Rack connector Typical Applications • Various 2-wire transmitters • Providing isolation and linearization for a 2-wire temperature transmitter • Linearizing weir flowmeter output to provide a linear-to- volume signal MODEL: 18JDL–A[1]66–R ORDERING INFORMATION • Code number: 18JDL-A[1]66-R Specify a code from below for [1]. (e.g. 18JDL-A366-R) Default setting (table next) will be used if not otherwise specified. No linearization data will be programmed if you don't specify type of linearization and required data. • Linearization data Code 1 segment data: Use Ordering Information Sheet (No. ESU-1669) to specify linearization data. Code 3 T/C, Code 4 RTD: Specify input sensor type and temperature range. LINEARIZATION CODE DEFAULT r a e n i L a t a d t n e m g e S : 1 2: Square root extraction ––– 3: Thermocouple K 0 – 1000°C 0 0 1 – 0 0 0 1 t P D T R : 4 °C INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) [1] LINEARIZATION 0: None 1: Segment data 2: Square root extraction 3: Thermocouple 4: RTD OUTPUT 1 Voltage 6: 1 – 5 V DC (Load resistance 2000 Ω min.) OUTPUT 2 Voltage 6: 1 – 5 V DC (Load resistance 2000 Ω min.) POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) RELATED PRODUCTS • Programming Unit (model: PU-2x) • PC configurator software (model: JXCON) Downloadable at M-System’s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL SPECIFICATIONS Construction: Rack-mounted; terminal access via screw terminals on the front and connector on the rear; terminal cover provided Connection Input: M3.5 screw terminals (torque 0.8 N·m) Output 1: Connector Output 2: M3.5 screw terminals (torque 0.8 N·m) |
类似零件编号 - 18JDL-A366-R |
|
类似说明 - 18JDL-A366-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |