| 数据搜索系统,热门电子元器件搜索 |
|
18KPP-322-R 数据表(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
18KPP-322-R 数据表(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 4 page ![]() MODEL: 18KPP 18KPP SPECIFICATIONS ES-0461 Rev.1 Page 1/4 http://www.m-system.co.jp/ Rack-mounted DCS Signal Conditioners 18K-RACK PULSE ISOLATOR Functions & Features • output frequency = input frequency • Built-in sensor power supply type • Module can be retracted without removing wiring for an insulation test • Optional power switch MODEL: 18KPP–[1]22–R[2] ORDERING INFORMATION • Code number: 18KPP-[1]22-R[2] Specify a code from below for each [1] and [2]. (e.g. 18KPP-322-R/S) • Input Pulse (e.g. 0 - 1000 Hz) [1] INPUT 1: Mechanical contact (max. 5 Hz) 2: Open collector (max. 10 kHz) 3: Voltage pulse (max. 10 kHz) 4: Two-wire current pulse, receiving resistor 200 Ω (max. 10 kHz) 5: Two-wire current pulse, receiving resistor 510 Ω (max. 10 kHz) 6: Two-wire current pulse, receiving resistor 1 kΩ (max. 10 kHz) OUTPUT 1 2: Open collector (max. 10 kHz) OUTPUT 2 2: Open collector (max. 10 kHz) (Output 1 and 2 frequency is equal) POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS Power Switch blank: None /S: With power switch GENERAL SPECIFICATIONS Construction: Rack-mounted; terminal access via screw terminals on the front and connector on the rear; terminal cover provided Connection Input: M3.5 screw terminals (torque 0.8 N·m) and connector Output 1: Connector Output 2: M3.5 screw terminals (torque 0.8 N·m) and connector Power input: Supplied from connector Screw terminal: Nickel-plated steel Isolation: Input to output 1 to output 2 to power Frequency range: Input and output are the same. Chattering protection: Filter provided for mechanical contact input INPUT SPECIFICATIONS Excitation: 12 V DC ±10 % @ 40 mA; shortcircuit protection ■ Open Collector Input pulse sensing: DC coupled Pulse width time requirement: ≥ 20 μsec. for ON and OFF Sensing: Approx. 12 V DC @ 3 mA ON/OFF level: ≤ 200 Ω / 5 V for ON, ≥ 100 kΩ / 7 V for OFF ■ Mechanical Contact Input pulse sensing: DC coupled Pulse width time requirement: ≥ 20 msec. for ON and OFF Sensing: Approx. 12 V DC @ 3 mA ON/OFF level: ≤ 200 Ω / 5 V for ON, ≥ 100 kΩ / 7 V for OFF Time constant: 10 msec. (able to cancel it by changing jumper, J6) ■ Voltage Pulse: Square or sine waveform Input pulse sensing: AC coupled Input impedance: ≥ 10 kΩ (Refer the graph and tables below for waveform, detection level range, the minimum amplitude, pulse width (duty ratio) and frequency requirements) |
类似零件编号 - 18KPP-322-R |
|
类似说明 - 18KPP-322-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |