MODEL: 18PP
18PP SPECIFICATIONS
ES-1861 Rev.7 Page 2/3
http://www.m-system.co.jp/
INPUT SPECIFICATIONS
Excitation: 12 V DC ±10 % @ 40 mA; shortcircuit protection
■ Open Collector
Input pulse sensing: DC coupled
Pulse width time requirement: ≥ 20 μsec. for ON and OFF
Sensing: Approx. 12 V DC @ 3 mA
ON/OFF level: ≤ 200 Ω / 5 V for ON, ≥ 100 kΩ / 7 V for OFF
■ Mechanical Contact
Input pulse sensing: DC coupled
Pulse width time requirement: ≥ 20 msec. for ON and OFF
Sensing: Approx. 12 V DC @ 3 mA
ON/OFF level: ≤ 200 Ω / 5 V for ON, ≥ 100 kΩ / 7 V for OFF
Time constant: 10 msec. (able to cancel it by changing
jumper, J6)
■ Voltage Pulse: Square or sine waveform
Input pulse sensing: AC coupled
Input impedance: ≥ 10 kΩ
(Refer the graph and tables below for waveform, detection
level range, the minimum amplitude, pulse width (duty
ratio) and frequency requirements)
Square Waveform
Pulse width is the smaller of TH or T L.
Duty ratio = frequency
× TH × 100 (%)
Sine or similar waveform
The input frequency range is 10 Hz to 10 kHz.
1 – 50Vp-p
TH
TL
0V
1 – 50Vp-p
Detection level range
: -50 to +50 V; max. 50 Vp-p
Waveform requirements
Square Waveform
FREQUENCY RANGE
AMPLITUDE
PULSE WIDTH & DUTY RATIO
0 to 10 kHz
1 to 3Vp-p
Duty 50 ±10%
0 to 10 kHz
Min. 3Vp-p
Min. 60 µsec.*
*When the frequency is 6 kHz or more, the pulse
width is 30 µsec. or more.
Sine or similar waveform
FREQUENCY RANGE
AMPLITUDE
PULSE WIDTH & DUTY RATIO
50 Hz to 10 kHz
1 to 3Vp-p
-
10 Hz to 10 kHz
Min. 3Vp-p
-
■ Two-wire Current Pulse
Input pulse sensing: AC coupled
Refer to the table above for the minimum amplitude, pulse
width (duty ratio) and frequency requirements.
Convert the current to the voltage for the amplitude.
OUTPUT SPECIFICATIONS
Open collector
Rating: 30 V DC @ 100 mA (resistive load)
Maximum frequency: 10 kHz
Saturation voltage: 0.5 V DC
INSTALLATION
Current consumption: Approx. 80 mA
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Standard Rack 18BXx or 18KBXx
Weight: 150 g (0.33 lb)
PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(input to output 1 or output 2 or power)
500 V AC @ 1 minute
(output 1 to output 2 to power)
1500 V AC @ 1 minute
(input or output or power to ground)



Html Pages

1 2 3


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com