数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

40DCT-A2-R 数据表(PDF) 3 Page - M-System Co.,Ltd.

部件名 40DCT-A2-R
功能描述  Digital Panel Meters 40 Series
PDF  7 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  MSYSTEM [M-System Co.,Ltd.]
网页  https://www.m-system.co.jp/
标志 MSYSTEM - M-System Co.,Ltd.

40DCT-A2-R 数据表(HTML) 3 Page - M-System Co.,Ltd.

  40DCT-A2-R Datasheet HTML 1Page - M-System Co.,Ltd. 40DCT-A2-R Datasheet HTML 2Page - M-System Co.,Ltd. 40DCT-A2-R Datasheet HTML 3Page - M-System Co.,Ltd. 40DCT-A2-R Datasheet HTML 4Page - M-System Co.,Ltd. 40DCT-A2-R Datasheet HTML 5Page - M-System Co.,Ltd. 40DCT-A2-R Datasheet HTML 6Page - M-System Co.,Ltd. 40DCT-A2-R Datasheet HTML 7Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 3 / 7 page
background image
MODEL: 40DCT
40DCT SPECIFICATIONS
ES-9538 Rev.8 Page 3/7
https://www.m-system.co.jp/
DISPLAY HOLD COMMAND
Displayed value is held with an external HOLD command input. Connect the contacts across HOLD to COM.
(Isolate with photo-coupler or relay as terminals 3 and 4 are not isolated to input signal, terminals 1 and 2.)
L
HOLD
H
L
HOLD
H
Twisted pair cable
Twisted pair cable
3
4
COM
(a) Photo-Coupler
(b) Relay
Relay
Photo-Coupler
HOLD
3
4
COM
HOLD
EXTERNAL VIEW
(2) Sticker Label
(1) Front Panel
(5) Disp/
Button
(3) 4-digit Display
(4) Polarity Indicator
(6) Scale/
Button
(8) Up Button
(7) Shift Button
■ FUNCTION TABLE
No.
COMPONENT
FUNCTIONS
(1)
Front panel
Removed at configuration.
(2)
Sticker label
Engineering unit label position
(3)
4-digit display
4-digit LED display. Range: 0 to 9999 (not including decimal point)
(4)
Polarity indicator
Turns on when negative value is displayed.
(5)
Disp/
button
Used to move on to the display setting modes, to shift through setting items in each setting mode,
or shift through display digits in each setting item.
(6)
Scale/
button
Used to move on to the scaling setting modes, to shift through setting items in each setting mode,
or shift through display digits in each setting item.
(7)
Shift button
Used to move on to the setting standby status.
(8)
Up button
Used to select setting value.



Html Pages

1 2 3 4 5 6 7


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com