| 数据搜索系统,热门电子元器件搜索 |
|
71VR1-E00-R 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
71VR1-E00-R 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 7 page ![]() MODEL: 71VR1 71VR1 SPECIFICATIONS ES-7403 Rev.17 Page 3/7 https://www.m-system.co.jp/ [Table 2 (RTD input)] Overrange input (out of the usable range) is handled as burnout. RTD USABLE RANGE (˚ C) CONFORMANCE RANGE (˚C) Pt 100 (JIS ’97, IEC) Pt 100 (JIS ’89) JPt 100 (JIS ’89) Pt 50 (JIS ’81) Ni 100 Cu 10 @25˚ C Cu 50 -240 to +900 -240 to +900 -236 to +560 -236 to +700 -100 to +252 -212 to +312 -100 to +200 -200 to +850 -200 to +660 -200 to +510 -200 to +649 -80 to +250 -50 to +250 -50 to +150 OUTPUT SPECIFICATIONS ■ Network Interface • Modbus-RTU: Retrievable analog data is Int data (signed 16 bits) only. Transmission: Half-duplex, asynchronous, no procedure Interface: Conforms to TIA/EIA-485-A Max. transmission distance: 500 meters Baud rate: 4800, 9600, 19200, 38400 bps Data bit: 8 bits Parity: Odd Stop bit: 1 bit Max. number of nodes: 15 (except the master) Media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) • Infrared Interface Interface: IrDA Max. transmission distance: ≤ 0.2 m (with COP-IRDA and 71VRCFG) ■ Contact Output (Do1, Do2) • Relay Output Relay rating: 250 V AC @5 A (cos ø = 1) 30 V DC @5 A (resistive load) Maximum switching voltage: 250 V AC or 30 V DC Maximum switching power: 1250 VA or 150 W Minimum load: 5 V DC @10 mA Mechanical life: 2 × 107 cycles INSTALLATION Power consumption • AC: Approx. 7 VA at 100 V Approx. 10 VA at 240 V • DC: Approx. 6 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Panel flush mounting Weight: 550 g (1.21 lb) PERFORMANCE Conversion accuracy DC input: ±0.1% ±1 digit Thermocouple input: ±1°C (±2°C for B, R, S, C, PR) RTD input: ±1°C (±3°C for Cu 10) CJC error: ±2°C max. at 25°C ±10°C ±4°C max. for R, S, PR Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) (±0.05 %/°C (±0.03 %/°F) for Cu 10) of max. span Response time: ≤ 0.5 sec. for DC input with the sample rate set to 100 msec. ≤ 2.5 sec. for T/C, RTD input with the sample rate set to 500 msec. Response time of alarm output, 0 – 100 % at 90 % setpoint. Line voltage effect: ±0.1 % over voltage range Calendar clock accuracy: Monthly deviation 2 minutes at 25°C Battery backup: Approx. one month Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (analog input each other to contact input to contact output 1 to contact output 2 to Modbus interface to power to FE) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (contact output) Installation Category II (power) Pollution degree 2 Analog input or contact input or contact output or network interface to power to FE: Reinforced insulation (300 V) Analog input each other to contact input to contact output each other to network interface: Basic insulation (300 V) RoHS Directive Protection against access to the terminal blocks: Finger protection (VDE 0660-514) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |