| 数据搜索系统,热门电子元器件搜索 |
|
73VR2106-N-R 数据表(PDF) 10 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
73VR2106-N-R 数据表(HTML) 10 Page - M-System Co.,Ltd. |
|
10 / 18 page ![]() MODEL: 73VR21 73VR21 SPECIFICATIONS ES-7395 Rev.29 Page 10/18 https://www.m-system.co.jp/ CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. FG JACK USB V(–) U(+) RJ-45 MODULAR JACK INPUT 8 7A 7B 7C INPUT 7 8A 8B 8C Analog Input Circuit 7 Analog Input Circuit 8 INPUT 10 9A 9B 9C INPUT 9 10A 10B 10C Analog Input Circuit 9 Analog Input Circuit 10 INPUT 12 11A 11B 11C INPUT 11 12A 12B 12C Analog Input Circuit 11 Analog Input Circuit 12 TRIGGER INPUT ALM+ ALM– ALARM OUTPUT TRG+ TRG– Isolated Alarm Output Isolated Trigger Input C B A ext. wire + – + – C B A C B A ext. wire – + – + C B A + – A B B ■ DC INPUT ■ T/C INPUT • Upscale / No Burnout ■ T/C INPUT • Downscale Burnout ■ RTD INPUT Input Connection Examples Note 1: Note 2: Note 3: Note 4: In order to prevent instability in measured values caused by noise entering through the I/O terminals, grounding the signal shield to a most stable earth point in the environment is recommended. The smaller is common mode voltage (DC and AC) between C terminals and between C and FG, the better is measuring accuracy. Connecting between C terminals and if possible to FG will yield the best accuracy. Resistor modules (model: REM3-250) can be connected to 1A through 12C terminals to convert current inputs into voltage. However, it is not recommended when TC inputs are mixed because the heat developed on and around the REM3 affects the cold junction compensation performance. We recommend that REM3 be connected on a separate terminal board. When the internal temperature sensors are used for CJC, temperature imbalance around the terminal block affects greatly the CJC accuracy. In order to minimize such imbalance, do not use wires of large diameter which has large heat dissipation. Be sure to close the terminal cover. Do not expose the module directly in the line of wind from a cooling fan. CJC SENSOR POWER Ethernet 10BASE-T / 100BASE-TX Micro Computer Control Module *1. Usable terminals depend upon the number of inputs. metal leg INPUT 2 1A 1B 1C INPUT 1 2A 2B 2C Analog Input Circuit 1 Analog Input Circuit 2 INPUT 4 3A 3B 3C INPUT 3 4A 4B 4C Analog Input Circuit 3 Analog Input Circuit 4 INPUT 6 5A 5B 5C INPUT 5 6A 6B 6C Analog Input Circuit 5 Analog Input Circuit 6 *1 CJC SENSOR metal leg |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |