2 / 5 page ![]() MODEL: AECT AECT SPECIFICATIONS ES-0137 Rev.4 Page 2/5 http://www.m-system.co.jp/ [7] POWER INPUT AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC V: 48 V DC P: 110 V DC [8] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to DC output to alarm output 1 to alarm output 2 to power Input waveform: Up to 15 % of 3rd harmonic content Overrange output: 0 to 120 % at 1 – 5 V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) Setpoint adjustments: Thumbwheel switches (front); 0 – 99 % independently; 1 % increments Hysteresis (deadband) adjustments: Thumbwheel switches (front); 0.5, 1 – 9 % independently; 1 % increments (SW position 0 = 0.5); [Lo SP + Hysteresis] ≤ 102 Front LEDs: Red lights turn on when the coils are energized. INPUT SPECIFICATIONS Frequency: 50 or 60 Hz Input burden: 0.5 VA maximum Overload capacity: 500 % of rating for 5 sec., 120 % continuous Operational range: 0 – 100 % of rating OUTPUT SPECIFICATIONS ■ DC Output •DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 7 V maximum •DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 1 mA maximum; at ≥ 0.5 V ■ Alarm Output: Relay contact 100 V AC @ 1 A (cos ø = 1) 120 V AC @ 1 A (co s ø= 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage: 380 V AC or 125 V DC Maximum switching power: 120 VA or 30 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 x 107 cycles For maximum relay life with inductive loads, external protection is recommended. Alarm Trip Operation Terminal No. in parentheses Trip Operation in Power Failure •Output Code: 1 & 4 •Output Code: 2 & 3 0 50 100 ▲ Input (%) Output 2 Setpoint ▲ Output 1 Setpoint Output 1 (9-15)ON Output 2 (1-11)ON (1-2)ON (9-10)ON |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |