| 数据搜索系统,热门电子元器件搜索 |
|
DLA1-2C1-R 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
DLA1-2C1-R 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 33 page ![]() MODEL: DLA1 DLA1 SPECIFICATIONS ES-6510 Rev.9 Page 2/33 http://www.m-system.co.jp/ Isolation: I/O to transmission section to power Station No. setting: 2 rotary switches; 00 – FF (256) ■ Controller & Transmission Sections Power indicator: Red LED turns ON in normal conditions; OFF when the voltage level becomes low. RUN indicator: Red LED turns OFF in error. ■ I/O Section Contact I/O indicator LED: Red LEDs turn on when the respective I/O channels are ON. Analog I/O CPU RUN indicator LED: Red LED turns ON when the CPU function proves normal, OFF in error. ■ RUN Contact Output: Contact opens in error. Rated load: 100 V AC or 30 V DC @ 1 A (resistive load) Maximum switching voltage: 120 V AC or 30 V DC Maximum switching power: 100 VA or 30 W Minimum load: 5 V DC @ 10 mA Error detection •Communication: The receiver units detect loss of communication and wire break. •CPU: Watch-dog timer •Power voltage: Detects when the voltage supply to the CPU drops by 10 %. MULTIPLEX COMMUNICATION Communication: Half-duplex, synchronous Transmission: Conform to RS-422, EIA Transmission speed: 125 kbps Protocol: SIN-NET (M-System's; data format conforms to SDLC) Error check: CRC ■ Twisted-pair Cable Cable: CPEV-0.9 dia. Connection: Euro Type connector terminal (Applicable wire size: ≤ 1.25 mm2, stripped length 8 mm) Transmission Distance: 1 kilometer max. with 16 units connected; 3 kilometers max. between 2 stations each of which consists of 3 units Terminator: Incorporated (Remove the attached jumper pin when the unit is not located at the end of transmission line.) ■ Fiber Optics Cable Link: JIS F07 connector (Consult factory for details) Transmission distance: 1 kilometer max. with PCF Transmission loss: 7 dB max. ■ Twisted-pair – Fiber Optics: Converting signals between two media and waveform shaping INSTALLATION Power consumption •AC: Approx. 17.5 VA max. •DC: Approx. 17 W max. (1.1 A with 24 V) Grounding: Not required in normal environments; 100 Ω or less grounding resistance in noisy environments Operating temperature: -5 to + 50°C (23 to 122°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface; Rack Mounting Frame (model: BX-1DL) available Weight: 2 kg (4.4 lb) PERFORMANCE Permissible power failure duration: ≤ 20 ms Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (I/O to transmission to power to ground) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |