| 数据搜索系统,热门电子元器件搜索 |
|
L53U-1211-R 数据表(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
L53U-1211-R 数据表(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 9 page ![]() MODEL: L53U L53U SPECIFICATIONS ES-1958 Rev.13 Page 3/9 https://www.m-system.co.jp/ Pulse rate selectable within 0.1 – 10 000.0 kWh/p, kvarh/p, kVAh/p INSTALLATION Power consumption •AC: < 10 VA •DC: < 3 W Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: DIN rail Weight: 320 g (0.71 lb) PERFORMANCE Accuracy (at 23°C ±10°C or 73.4°F ±18°F, 45 – 65 Hz) Voltage: ±0.3 % (±0.2 % for Option /H)*1 Current: ±0.3 % (±0.2 % for Option /H)*1 Power: ±0.5 %*1 Power factor: ±0.5 % Frequency: ±0.1 %*1 Energy: ±1 % (±0.5 % for Option /H*2) Harmonic contents: ±1 %*1 Analog output: Accuracy of assigned measurand or ±0.2 %, whichever is greater. *1. Percentage of the spans: 480 V for voltage; 1 A or 5 A for current; and 4155 W (5 A) or 831 W (1 A) for active power The described accuracy levels are ensured at the input 1 % or more for phase 2 current with 3-phase/3-wire unbalanced load, for neutral current with 3-phase/4-wire unbalanced load, and neutral current with 1-phase/3-wire. *2. Accuracy level: Active energy class 0.5S according to IEC 62053-22 (Reactive energy class 2 according to IEC 62053-23) Sampling rate: 64 samples per cycle Data update period: Harmonic contents and frequency: ≤ 1.1 sec. Other: ≤ 600 msec. Response time: ≤ 2 sec. (0 – 99 %), ≤ 3 sec. for frequency and harmonic contents Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 4000 V AC @1 minute (voltage input or current input or discrete input or discrete output or Modbus or configurator jack or analog output to auxiliary power) 2500 V AC @1 minute (voltage input to current input to discrete input to discrete output to Modbus or configurator jack or analog output) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category III (input) (Measurement Category II if the auxiliary power supply code is R) Measurement Category II (output) Installation Category II (auxiliary power) Pollution Degree 2 Input to auxiliary power: Reinforced insulation (550 V) Output to auxiliary power: Reinforced insulation (300 V) Input to output: Basic insulation (550 V) RoHS Directive |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |