3 / 5 page ![]() MODEL: M7EASDY M7EASDY SPECIFICATIONS ES-7763 Rev.12 Page 3/5 https://www.m-system.co.jp/ OUTPUT SPECIFICATIONS ■ Quad Alarm Relay rating: 100 V AC @ 1 A (cos ø = 1) 120 V AC @ 1 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage: 250 V AC or 125 V DC (Limited to the max. voltage 150 V AC or to the use for Measurement Category I in order to conform with EU Directive) Maximum switching power: 120 VA or 30 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles ■ DUAL ALARM Relay rating: 100 V AC @ 4 A (cos ø = 1) 120 V AC @ 4 A (cos ø = 1) 240 V AC @ 2 A (cos ø = 1) 30 V DC @ 4 A (resistive load) Maximum switching voltage: 250 V AC or 125 V DC (Limited to the max. voltage 150 V AC or to the use for Measurement Category I in order to conform with EU Directive) Maximum switching power: 480 VA or 150 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles 0 50 100 Input % LL L HH H L2 (5–7) L3 (5–8) L4 (3–9) L1 (3–6) ON ON OFF ON ON OFF OFF OFF • Example Quad N.O. contacts (LL, L, H, HH) Alarm Trip Operation Terminal No. in parentheses Trip operation in power failure Output code 2 : All relays turn OFF. Output code 3 : All relays turn ON. Output code 5 : Terminals 3 – 9, 5 – 8 turn ON. LINEARIZATION ■ Linearization Types Linear: No linearization Square root: The input is square root extracted. User table Calibration points: Max. 128 points; the input % and linearized value in scaling are specified in pairs. Selectable range: -7.5 to +107.5 % as input %; -9999 to +9999 as linearized values ■ Low-end Cutout: Low-end cutout (Low Cut) point selectable within the range of 0 to 100 %. With the linear or user table output type, the output signal is forcibly set to 0 % for the input lower than the low-cut point. With the square root extraction, the output signal is linear to the input when the latter is lower than the low-cut point. INPUT • Linear or User Table • Square Root 0 Low-end cutout point INPUT 0 Low-end cutout point INSTALLATION Power consumption •AC: Approx. 5 VA at 100 V Approx. 7 VA at 200 V Approx. 8.5 VA at 264 V •DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail With 4-point alarm type, leave extra 1-unit space on both sides of the unit if all 4 relay coils are to be energized in normal conditions. Weight: 200 g (0.44 lb) PERFORMANCE in percentage of FS input Setpoint accuracy (trip point accuracy): ±(0.1 % of FS + 1 digit) (gain ≤1) ±(0.1 % × gain of FS + 1 digit) (gain >1) Display accuracy: ±(0.1 % of FS + 1 digit) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |