3 / 6 page ![]() MODEL: M7EASV M7EASV SPECIFICATIONS ES-7762 Rev.13 Page 3/6 https://www.m-system.co.jp/ INPUT SPECIFICATIONS ■ DC Current: Shunt resistor attached to the input terminals (0.5 W) Operational range: 0 – 70 mA DC with 100 Ω, 0.5 W Input range: 0 – 50 mA DC Minimum span: 2 mA Factory default setting: 4 – 20 mA DC Offset: Lower range can be any specific value within the input range provided that the minimum span is maintained. ■ DC VOLTAGE Code S1 (narrow spans) Operational range: -1150 – +1150 mV DC Input range: -1000 – +1000 mV DC Minimum span: 10 mV Factory default setting: 0 – 100 mV DC Code S2 (wide spans) Operational range: -11.5 – +11.5 V DC Input range: -10 – +10 V DC Minimum span: 0.1 V Factory default setting: 1 – 5 V DC Offset: Lower range can be any specific value within the input range provided that the minimum span is maintained. OUTPUT SPECIFICATIONS ■ Quad Alarm Relay rating: 100 V AC @ 1 A (cos ø = 1) 120 V AC @ 1 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage: 250 V AC or 125 V DC (Limited to the max. voltage 150 V AC or to the use for Measurement Category I in order to conform with EU Directive) Maximum switching power: 120 VA or 30 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles ■ DUAL ALARM Relay rating: 100 V AC @ 4 A (cos ø = 1) 120 V AC @ 4 A (cos ø = 1) 240 V AC @ 2 A (cos ø = 1) 30 V DC @ 4 A (resistive load) Maximum switching voltage: 250 V AC or 125 V DC (Limited to the max. voltage 150 V AC or to the use for Measurement Category I in order to conform with EU Directive) Maximum switching power: 480 VA or 150 W Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles 0 50 100 Input % LL L HH H L2 (5–7) L3 (5–8) L4 (3–9) L1 (3–6) ON ON OFF ON ON OFF OFF OFF • Example Quad N.O. contacts (LL, L, H, HH) Alarm Trip Operation Terminal No. in parentheses Trip operation in power failure Output code 2 : All relays turn OFF. Output code 3 : All relays turn ON. Output code 5 : Terminals 3 – 9, 5 – 8 turn ON. INSTALLATION Power Consumption •AC: Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 264 V •DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 200 g (0.44 lb) PERFORMANCE in percentage of FS input Setpoint accuracy (trip point accuracy): ±(0.1 % of FS + 1 digit) Display accuracy: ±(0.1 % of FS + 1 digit) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |