| 数据搜索系统,热门电子元器件搜索 |
|
MAKF 数据表(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
MAKF 数据表(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 5 page ![]() MODEL: MAKF MAKF SPECIFICATIONS ES-8143 Rev.3 Page 2/5 http://www.m-system.co.jp/ PERFORMANCE Response time: ≤ 20 nsec. Maximum discharge current: 20kA × twice (8/20 μsec.) Nominal discharge current: 5 kA (8/20 μsec.) Insulation resistance: ≥ 100 MΩ with 500 V DC (line to alarm output) Dielectric strength: 2000 V AC @ 1 minute (line to alarm output) Leakage current: ≤ 1 mA at the discharge voltages listed in the table below. MODEL Uc DISCHARGE Up VOLTAGE @1.0kA (8/20 µs) @5kA (8/20 µs) (AC) (V) (Vmin) (Vmax) (Vmax) MAKF-120 150 250 600 800 MAKF-240 275 420 1000 1400 MAKF-280 320 460 1100 1500 MAKF-400 440 670 1500 2100 MAKF-480 530 820 1800 2500 Uc = Maximum continuous operational voltage Up = Voltage protection level CONNECTION EXAMPLES ■CONFIGURATION EXAMPLE: Single-phase / 2-wire connection Protected Device Circuit Breaker ‘a’ Cross-wiring Grounding (100Ω or less) MAKF G *1 *5 *2 *3 *4 *1. *2. *3. *4. *5. The circuit breaker must be installed. Molded-case circuit breakers (MCCB), earth leakage circuit breakers (ELCB) or current-limiting fuses (slow-blow type only) can be used. The rated interrupting capacity of the circuit breaker must be greater than the highest amount of current that could be available in the circuit. The MCCB or ELCB must has elements at both poles. Time-delay type over-current protection is recommended for an ELCB. Recommended sensitivity current rating: 30mA If the rated current of the circuit breaker ‘a’ exceeds 30A, or if the loss of power supply to the protected device should be prevented when the circuit breaker ‘a’ blows due to a surge protector failure, install the circuit breaker ‘b’ (rated current 20-30 A) at the branch circuit. Cable length between the branch point and the grounding: 0.5 meters or less recommended. The protected device’s metal housing must be cross-wired to the ground terminal of the MAKF. If the protected device has no ground terminal, ground only the MAKF. In order to protect an electronic circuit such as switching regulartors, we recommend to use surge protectors which have serial impedance incorporated such as M-System’s models MAX, MMA, MAH. Circuit Breaker ‘b’ |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |